WARNING! Important safety instructions. Carefully
read and comply with all the warnings and instruc-
tions that come with the product as incorrect instal-
lation can cause injury to people and animals and
damage to property. The warnings and instructions
give important information regarding safety, instal-
lation, use and maintenance. Keep hold of instruc-
tions so that you can attach them to the technical
file and keep them handy for future reference.
GENERAL SAFETY
This product has been designed and built solely for
the purpose indicated herein. Uses other than those
indicated herein might cause damage to the product
and create a hazard.
- The units making up the machine and its installation
must meet the requirements of the following European
Directives, where applicable: 2004/108/EC, 2006/95/
EC, 99/05/EC and later amendments. For all countries
outside the EEC, it is advisable to comply with the
standards mentioned, in addition to any national
standards in force, to achieve a good level of safety.
- The Manufacturer of this product (hereinafter referred
to as the "Firm") disclaims all responsibility resulting
from improper use or any use other than that for
which the product has been designed, as indicated
herein, as well as for failure to apply Good Practice in
the construction of entry systems (doors, gates, etc.)
and for deformation that could occur during use.
- Before commencing installation, check the product
for damage.
- Make sure the stated temperature range is compatible
with the site in which the automated system is due to
be installed.
- Do not install this product in an explosive atmosphere:
the presence of flammable fumes or gas constitutes a
serious safety hazard.
- Disconnect the electricity supply before performing
any work on the system. Also disconnect buffer bat-
teries, if any are connected.
- Before connecting the power supply, make sure the
product's ratings match the mains ratings and that a
suitable residual current circuit breaker and overcur-
rent protection device have been installed upline from
the electrical system. Ensure that there is an automa-
tion, switch or 16A all-pole thermal magnetic circuit
breaker on the grid to enable complete disconnection
in the conditions of overvoltage III category.
- Make sure that upline from the mains power supply
there is a residual current circuit breaker that trips at
no more than 0.03A as well as any other equipment
required by code.
- Make sure the earth system has been installed cor-
rectly: earth all the metal parts belonging to the entry
system (doors, gates, etc.) and all parts of the system
featuring an earth terminal.
- Only use original spare parts for any maintenance or
repair work. The Firm disclaims all responsibility for the
correct operation and safety of the automated system
if parts from other manufacturers are used.
- Do not make any modifications to the automated
system's components unless explicitly authorized by
the Firm.
- Instruct the system's user on what residual risks may be
INSTALLER WARNINGS
encountered, on the control systems that have been
applied and on how to open the system manually in
an emergency. give the user guide to the end user.
- Dispose of packaging materials (plastic, cardboard,
polystyrene, etc.) in accordance with the provisions
of the laws in force. Keep nylon bags and polystyrene
out of reach of children.
WIRING
WARNING! For connection to the mains power supply,
use: a multicore cable with a cross-sectional area of at
least 5x1.5mm
phase power supplies or 3x1.5mm
supplies (by way of example, type H05 VV-F cable can
be used with a cross-sectional area of 4x1.5mm
connect auxiliary equipment, use wires with a cross-
sectional area of at least 0.5 mm
- Only use pushbuttons with a capacity of 10A-250V
or more.
- Wires must be secured with additional fastening near
the terminals (for example, using cable clamps) in
order to keep live parts well separated from safety
extra low voltage parts.
- During installation, the power cable must be stripped
to allow the earth wire to be connected to the relevant
terminal, while leaving the live wires as short as pos-
sible. The earth wire must be the last to be pulled
taut in the event the cable's fastening device comes
loose.
WARNING! safety extra low voltage wires must be kept
physically separate from low voltage wires.
Only qualified personnel (professional installer) should
be allowed to access live parts.
DECLARATIONS OF CONFORMITY CAN BE FOUND
AT
http://www.bft-automation.com/CE
INSTRUCTIONS FOR USE AND ASSEMBLY CAN BE
FOUND IN THE DOWNLOAD SECTION.
Anything that is not explicitly provided for in the
installation manual is not allowed. Proper ope-
ration can only be guaranteed if the information
given herein is complied with. The Firm shall not
be answerable for damage caused by failure to
comply with the instructions featured herein.
While we will not alter the product's essential
features, the Firm reserves the right, at any time,
to make those changes deemed opportune to
improve the product from a technical, design or
commercial point of view, and will not be required
to update this publication accordingly.
AVVERTENZE PER L'INSTALLATORE D812160_04
or 4x1.5mm
when dealing with three-
2
2
.
2
SCRAPPING
Materials must be disposed of in accordance
with the regulations in force. Do not throw
away your discarded equipment or used
batteries with household waste. You are
responsible for taking all your waste electri-
cal and electronic equipment to a suitable
recycling centre.
for single-phase
2
). To
2
13
MIME AC -