1) GENERAL INFORMATION
Two-relay two-channel receiver supplied directly from
the mains 230V 50/60Hz, extremely compact, con-
trolled by a microcontroller with decoding, remote
control self-learning, antijamming digital filter to im-
prove radio performance even further.
The firmware developed for this receiver is extremely
flexible and intuitive and allows advanced functions
such as the independent change of the operating
modes for each channel.
This receiver is fitted with an integrated buzzer that
allows programming without having to physically ac-
cess the board.
It uses a SAW filter to improve selectivity and suppress
out-of-band interference.
Thanks to the use of suitably sized relays, with this
receiver both lights and electrical motors can be con-
trolled.
This module is fitted with a practical and efficient
low-consumption power supply unit (standby ≤0,3W)
characterized by a wide range of operating voltages
and is also protected from overvoltages at the mains
input.
Compliant with the I-ETS 300 220 and ETS 300 683 Eu-
ropean standards.
This manual will describe only the programming pro-
cedures used to control the lights. As to the program-
ming procedures to control the motor see: www.bft-
automation.com/area-download/.
2) GENERAL SAFETY
- The product is designed to operate only inside electrical
junction boxes or wall boxes, therefore its container is not
protected against liquid penetration but just basically
protected against the contact with solid parts (IP20). The
use in environments other than those the product has
been designed for is strictly forbidden.
- It is forbidden to open or pierce the plastic container of
the product, the parts inside it are live; do not cut or strip
the antenna wire since it is live.
- The device has no protection against overvoltages or short
circuits on outputs, therefore protection adequate to the
installed load/s (fuse or circuit breaker) must be provided.
- It is forbidden to install the receiver in SELV system
sections (i.e. bell circuits, video entry systems, 12/24V
spot lights, etc.)
- The control devices (buttons or switches) and the con-
necting cables must have isolation features suitable to
electrical systems with operating voltage no lower than
300VAC.
8)"MOTOR CONTROL" OPERATING MODE
Step by step
The motor carries out the Step by Step command, that is every time the radio/wall control
code is received, it will have to comply with the UP-STOP-DOWN-STOP-UP sequence
Up/stop
When the command is received, the receiver activates the relay for the set operating time,
when a second command is received it deactivates the relay.
Down/stop
When the command is received, the receiver activates the down relay for the set operating
time, when a second command is received it deactivates the relay.
14 -
MIME AC
INSTALLATION MANUAL
3) APPLICATIONS
Remote control for blinds and shutters, wireless control to
switch lights on, lighting intelligent management, addition
of light control points, energy saving, domotics actuator, etc
4) TECHNICAL SPECIFICATIONS
Power supply:
Capacity of the
output contacts:
Output
Storage temperature: - 40 / + 100°C
Operating
temperature range:
IP rating
Max. No. of
transmitters that
can be stored
Built-in Rolling-Code
radio-receiver
Setting of parameters
and options
Usable
transmitters
5) DIMENSIONS (FIG. A)
6) TERMINAL BOARD WIRING (FIG. B)
7) "MOTOR CONTROL" MODE FUNCTIONS
In the motor version there is a timeout (see fig. D5) that
the user can program, used to stop the command recei-
ved (by both TX and the local inputs) to protect the motor.
The relays cannot be active at the same time.
A change in activation will be preceded by both deacti-
vating for 500 ms minimum (400ms minimum).
110-230V~ 50/60 Hz*
5A/1250VA @
Cosφ= 1
250VAC
2 relays, 5A max
- 20 / + 40°C
IP 20
30
Frequency 433.92 MHz
LED and BUZZER programming