• ORP Probe Error -- If the CSM indicates that there is a problem with the ORP probe.
• ORP Low - Check Chlor -- If an ORP level of 350mV or less is detected. Check the chlo-
rinator for proper operation.
• ORP High - Check Chlor -- If an ORP level of 950mV or higher is detected. Check the
chlorinator for proper operation.
• ORP High - Chlor Off -- If an ORP level of 950mV or higher is detected and the chlorine
feed mode is ORP Auto Sensing, the chlorinator has been turned off. Check the chlorinator
for proper operation.
• ORP Timeout -Chlor Off -- If the unit has been chlorinating for more than the selected
sanitizer timeout without reaching the desired level, the chlorinator has been turned off. Press
the "+" button to reset the alarm and resume chlorination.
• Ambient Sensor -- If the internal (ambient) sensor is either open or short circuit.