Units
Metric
The AquaRite Pro can display temperature and units in Metric (ºC and g/L)
or English (ºF and PPM). Make the desired selection here.
Display Light
On for 60 sec
This function controls the backlight on the display. Select between "Always
On" and "On for 60 seconds". If "On for 60 seconds" option is selected, then
the backlight will automatically turn off 60 seconds after the last key is pressed
and will stay off until next time a key is pressed.
Beeper
Enabled
When "Enabled", the keypad will beep every time a key is pressed. If this
audible indication is not desired, select "Disabled".
Reset Config. to
Default Press +
Are you sure?
+ to proceed
Config. reset
Confirmed
Use this function to erase all previous system configuration and reset all
configuration parameters back to the factory default values. This function
is NOT reversible, be careful
Operation
Assuming that the water chemical levels are in the recommended range, there are three factors
that you can control which directly contribute to the amount of chlorine the AquaRite Pro will
generate:
1. filter run time each day (hours)
2. the desired output % setting or ORP setting (when using AQL-CHEM)
3. the amount of salt in the pool
The filter pump timer should be set so that entire volume of pool water passes through the filter
each day. For pools with high chlorine demand, the timer may have to be set longer to generate
enough chlorine.
If optional AQL-CHEM sensing is NOT used. To find the optimum desired output % setting,
start at approximately 50%. Test the chlorine level every few days and adjust the setting up or
down accordingly. It usually takes 2-3 adjustments to find the ideal setting for your pool/spa
and after that, it should only take minor, infrequent adjustments. Because the chlorine demand
of the pool increases with temperature, most people find they have to adjust the desired output
up at the peak of the summer and down during the colder periods.
The AquaRite Pro automatically stops generating when the pool water temperatures drops below
12°C. This is usually not a problem because bacteria and algae
11 / 20
Toggle between Metric and English
Move to previous/next menu item
Toggle between Always On and On for 60 sec.
Move to previous/next menu item
Toggle between Enabled (default) and Disabled Beeper
Move to previous/next menu item
Initiate reset of all configuration parameters
Move to previous/next menu item (config. not reset)
Reset all configuration parameters
Move to previous/next menu item (config. not reset)
Move to previous/next menu item
AquaRite Pro
Rev. C