Abicor Binzel ABITIG MT 260W Mode D'emploi page 31

Masquer les pouces Voir aussi pour ABITIG MT 260W:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

®
ABITIG
MT
1
1
Coolant return hose
Fig. 3
Ventilate the entire cooling system as follows when used for the first time and after every hose
assembly change:
1 Disconnect the coolant return hose (1) from the re-circulating cooling unit (2) and hold it
over a collecting device.
2 Close the opening at the coolant return hose (1) and open it again by repeatedly and
abruptly releasing it, until the coolant is flowing continuously and without air bubbles into the
collecting device.
3 Switch off the re-circulating cooling unit (2) and reconnect the coolant return hose (1).
7 Operation
DANGER
Shortness of breath and poisoning caused by inhaling phosgene gas
When welding workpieces that have been degreased with chlorinated solvents, phosgene
gas is formed.
• Do not inhale smoke and vapours.
• Ensure a sufficient supply of fresh air.
• Rinse the workpieces with clean water prior to welding.
• Do not place degreasing baths containing chlorine in the vicinity of the welding area.
DANGER
Risk of burns
During welding activities, sparks, glowing workpieces or hot slag can produce flames.
• Check the work area for flashpoints.
• Provide appropriate fire extinguishing equipment in the workplace.
• Allow workpieces to cool down after welding.
• Prior to performing welding work, properly fasten the ground clamp to the workpiece or
welding table.
BAL.0107 • 2020-04-15
Connecting the coolant
2
2
Re-circulating cooling unit
7 Operation
EN - 13

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Abitig mt 200Abitig mt 300wAbitig mt 400wAbitig mt 500w

Table des Matières