Preparing the calibration check
It is possible for you to check the calibration of the laser. To do this, position the device midway between 2 walls,
which must be at least 5 metres apart. Switch the device on (Laser cross ON). The best calibration results are
achieved if the device is mounted on a tripod.
1.
A1
2.
3.
A1
4.
!
If points A2 and A3 are more than 0,4 mm / m, the device is in need of calibration.
Contact your authorised dealer or else the UMAREX-LASERLINER Service Department.
10
GB
± 5°
± 0.4 mm / m
20 m
10 - 30 m
635 nm
2 / < 1 mW
4 x 1.5V alkaline batteries (type AA, LR6)
approx. 35 hours
0°C ... +40 °C
-10°C ... +70 °C
75 x 130 x 100 mm
525 g
1. Mark point A1 on the wall.
2. Turn the device through 180° and mark point A2.
You now have a horizontal reference between
points A1 and A2.
A2
Performing the calibration check
3. Position the device as near as possible
A2
A2
to the wall at the height of point A1.
4. Turn the device through 180° and mark
A3
point A3. The difference between points A2
A2
and A3 is the tolerance.
A3