Checking the vertical line:
Position the device about 5 m from a wall. Fix a plumb bob with a line of 2.5 m length on the wall, making
sure that the bob can swing freely. Switch on the device and align the vertical laser to the plumb line.
The precision is within the specified tolerance if the deviation between the laser line and the plumb line
is not greater than ± 1 mm.
Checking the horizontal line:
Position the device about 5 m from a wall and switch on the cross laser. Mark
point B on the wall. Turn the laser cross approx. 2.5 m to the right and mark
point C. Check whether the horizontal line from point C is level with point B
to within ± 1 mm. Repeat the process by turning the laser to the left.
!
Regularly check the adjustment before use, after transport and after extended periods of storage.

Technical data

(subject to technical changes without notice 19W45)
Self-levelling range
Accuracy
Levelling
Visibility (typical)*
Working range with hand receiver
Laser wavelength
Plumb laser wavelength
Reference beam wavelength
Laser class
Protection class
Power supply
Operating time
Operating conditions
Storage conditions
Dimensions (W x H x D)
Weight
* at max. 300 lux
EU directives and disposal
This device complies with all necessary standards for the free movement
of goods within the EU.
This product is an electric device and must be collected separately for disposal
according to the European Directive on waste electrical and electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=AJE
MasterCross-Laser 2GP
± 3°
± 0.2 mm / m
automatic
25 m
(depends on how the technology affects the difference
in brightness) 60 m
515 nm
635 nm
635 nm
2 / < 1 mW (EN 60825-1:2014)
IP 54
4 x 1.5V LR6 (AA)
approx. 4 hours
0°C ... 50°C, max. humidity 85% rH, no condensation,
max. working altitude 4000 m above sea level
-10°C ... 70°C, max. humidity 85% rH
66 x 100 x 125 mm
570 g (incl. batteries)
2,5 m