Battery Installation And Battery Type Setting (Wet Or Gel) - Clarke CR 28 BOOST Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ENGLISH

BATTERY INSTALLATION AND BATTERY TYPE SETTING (WET OR GEL)

According to the type of batteries (WET or GEL), set the machine and electronic board of the battery charger as follows:
Machine setting
1.
Turn the ignition key (41) to "I" and in the very fi rst seconds of machine operation pay attention to the following:
If the green warning light (37a) is fl ashing, the machine is set to GEL (compatible with AGM).
If the red warning light (37c) is fl ashing, the machine is set to WET.
2.
To change the settings, proceed as follows.
3.
Turn off the machine and turn the ignition key (41) to "0".
4.
Press and hold the switch (36), then turn the ignition key (41) to "I".
5.
Release the switch (36) at least 5 seconds after turning the machine on.
6.
Press again the switch (36) for a few seconds and check that the warning light of the required setting is fl ashing.
Battery charger setting
7.
Remove the screws (A, Fig. 1) and the panel (B).
8.
Turn the selector (C) to WET or GEL according to the type of batteries installed.
9.
Install the panel (B), then tighten the screws (A).
Battery installation
10.
Open the covers (51 and 58) and check that the tanks (60 and 61) are empty, otherwise drain them through the drain hose (10)
and the tap (24).
11.
Close the covers (51 and 58).
12.
Carefully lift the tank assembly (71).
13.
Install the batteries and connect them according to the diagram (76).
Battery charging
14.
Charge the batteries (see the procedure in Maintenance chapter).
12
Figure 1
Operator's Manual - CR 28 BOOST
S311218A
®

Publicité

Table des Matières
loading