3. Commissioning

Take care when unpacking the unit and accessories.
Place the soldering tool in the safety rest.
Insert the soldering iron plug in the connection socket (9) of
the control unit and lock by turning slightly to the right.
Check that the mains voltage matches the specification on
the identification plate and that the mains switch (7) is swit-
ched off. Connect the control unit to the mains (11). Switch
on the unit at the mains switch (7). The unit performs a self-
test when it is switched on, whereby all display elements (1)
are in operation.
Following this, the set temperature (specified value) is dis-
played for a brief period. The electronics system then swit-
ches automatically to the actual value display. The " "
symbol appears and the three fixed temperatures of tempe-
rature buttons I, II and III are displayed. The " " symbol
serves as a visual control check. When lit up permanently,
this indicates that the system is heating up. Flashing indica-
tes that service temperature has been reached.

3.1 Temperature setting

3.1.1 Individual temperature setting
As a rule, the display (1) shows the temperature actual
value. By actuating the UP or DOWN button (2) (3), the dis-
play switches to the currently set specified value. The tem-
perature symbol °C or °F flashes.
The specified value can now be changed by tapping or hol-
ding in the UP or DOWN button (2) (3) in the corresponding
direction. If the button is pressed permanently, the specified
value changes in fast mode. Approx. 2 s after the button is
released, the display switches automatically back to the
actual value.
3.1.2 Temperature setting with the temperature
buttons I, II, III
The specified value for the temperature can also be changed
via the 3 temperature buttons I, II, III.
ex works setting:
I 150 °C ( 300 °F)
II 350 °C ( 662 °F)
III 380 °C (716 °F)
35
By actuating a temperature button, the selected specified
value appears for approx. 2 s in the display. During this dis-
play, the temperature symbol flashes. After this, the display
switches back automatically to the actual value display.
3.1.3 Assignment of the temperature buttons I, II, III
The 3 temperature buttons I, II, III can be assigned with
temperature values as desired.
When the UP or DOWN button is actuated, the new tempe-
rature value is set (see 3.1.1).
The temperature symbol °C or °F flashes.
Following this, press and hold in the desired temperature
button I, II or III. When the button is pressed, the small dis-
play assigned to the temperature button also flashes and,
after 3 s, adopts the value of the large display. Release the
temperature button again.
The assignment of a temperature button with a low "set-
back" temperature, gives you the option of manual tempera-
ture decrease when the soldering iron is not being used.

4. Special functions

The special functions are splitted in two menu sections:
Special function menu 1: often used functions like STAND-
BY, OFFSET, SETBACK, ...
Special function menu 2: calibration function and REMOTE
Id.

Publicité