7. Charging Lithium Chemistry (LiPo/Li-lon/LiFe) Type Batteries
–
+
DEC
INC
Batt type
stop
Number
Charging
of Cells
Time
Charging Lithium Battery in Balance Mode
This function is for balancing the voltage of Lithium-polymer
battery cells individually while charging. In the balance mode,
the battery needs to have a balance lead to connect to the
balance port at the right side of the charger and the battery's
power leads to the output of the charger.
–
+
DEC
INC
Batt type
stop
Number
Charging
of Cells
Time
40
–
+
DEC
INC
Start
> 3 seconds
Enter
Start
Enter
Battery
Voltage
Charging
Charged
Current
Capacity
–
+
DEC
INC
Start
> 3 seconds
Enter
Start
Enter
Battery
Voltage
Charging
Charged
Current
Capacity
Professional Balance Charger, Discharger
Charging Lithium Battery in the Charge Mode
These methods for charging LiPo/Li-Ion/LiFe batteries without
a balance lead. The fi rst line on the left side of this screen
shows the type of battery chosen. The second line shows
the user set current on the left and the user set voltage on
the rights. After setting the current and voltage, press the
„START/ENTER" key for more than 3 seconds to start the
process (charge current range: 0.1-6.0 A, voltage range:
3.7-22.2 V).
The next display shows the number of cells you set up as „R"
and the number of cells the processor detects as „S". If both
numbers are identical, you can start charging by pressing the
„START/ENTER" button. If not, press the „BATT TYPE/STOP"
button to go back to the previous screen to carefully check
the number of cells of the battery pack before proceeding.
This next screen shows the real-time status during the charge
process. Press the „BATT TYPE/STOP" key once to stop
the charge process.
Charging in this mode is different from the normal modes
because the built-in processor monitors the voltage of each
individual cell and controls the input current fed into each
cell in order to equalize the voltage.
The fi rst line on the left side of this screen shows the type of
battery chosen. The second line shows the user set current
on the left and the user set voltage on the rights. After setting
the current and voltage, press the „START/ENTER" key for
more than 3 seconds to start the process (charge current
range: O.1-6.0 A, voltage range: 3.7-22.2 V).
The next display shows the number of cells you set up as „R"
and the number of cells the processor detects as „S". If both
numbers are identical, you can start charging by pressing the
„START/ENTER" button. If not, press the „BATT TYPE/STOP"
button to go back to the previous screen to carefully check
the number of cells of the battery pack before proceeding.
This next screen shows the real-time status during the charge
process. Press the „BATT TYPE/STOP" key once to stop
the charge process.