Professional Balance Charger, Discharger
6. Default User Preferences Setup
4
NIMH Sensitivity
D.Peak
DEC
NICD Sensitivity
D.Peak
DEC
5
Temp. Cut-off
ON
+
DEC
INC
DEC
6
Waste time
CHG/DCHG
+
DEC
INC
DEC
7
Safety timer
ON
+
DEC
INC
DEC
Default
+
DEC
INC
INC
Default
+
DEC
INC
INC
80C
+
DEC
INC
INC
5min
+
DEC
INC
INC
120min
+
DEC
INC
INC
NiMh and NiCd Delta Peak Sensitivity Setting
4
This feature sets the cutoff voltage for the automatic charge
termination of a NiMH and NiCd battery pack. The setting
can range from 5 to 20 mV per cell, the default is 12 mV
for NiCd batteries and 7 mV for NiMH, the parameters are
set individually for NiCd and NiMh batteries. If the cutoff
voltage is too high, there is a danger of overcharging the
battery, if it is too low there is a possibility of premature
charge termination. Refer to the battery manufacturer's
specifi cations to determine the proper setting. Once you
have established the desired settings press „START/ENTER"
to confi rm the setting then press „INC" to move on to the
next parameter.
5
Temperature Cutoff Setting
You can choose whether or not you want to use the automatic
temperature cut off when using the optional temperature sen-
sors. When turned on you can set the maximum temperature
at which the charger should allow the battery to reach during
charging. Once a battery reaches this temperature, the charge
or discharge process will be terminated to protect the battery.
Once you have established the desired settings press „START/
ENTER" to confi rm the setting then press INe to move on to
the next parameter.
Waste Time Setting
6
When charge/discharge cycling a battery the battery will
become warm. You can set a time delay ranging from 0 to
60 minutes after each charge/discharge process to allow
the battery to cool down before starting the next charge/
discharge cycle. Once you have established the desired
settings press „START/ENTER" to confi rm the setting then
press „INC" to move on to the next parameter.
Safety Timer Setting
7
When the charge process starts, the integrated safety timer
runs simultaneously. If an error occurs or the charge termi-
nation circuit cannot detect if the battery is fully charged,
this setting will terminate the charge process to prevent
overcharging. Use the Safety Timer Calculation below to
determine the proper setting.