6. Default User Preferences Setup
9
Capacity Cut-Off
ON
–
+
DEC
INC
DEC
10
Key Beep
Buzzer
DEC
11
Input power low
Cut-Off
38
5000mAh
–
+
DEC
INC
INC
ON
ON
–
+
DEC
INC
INC
10.0V
Professional Balance Charger, Discharger
Safety Timer Setting Calculation
8
To determine the correct safety time setting when charging
NiCd or NiMH batteries, divide the capacity by the current,
and then divide the result by 11.9. Set the results of this
calculation as the number of minutes for the safety timer
setting. If the charger stops at this time threshold, about
140% of the capacity will have been fed into the battery.
Example:
2000 mAh 2.0 A (2000/2.0=1000)/11.9 = 84 minutes.
Capacity Cutoff Setting
9
The charging software allows the user to create a maximum
charge capacity protection setting. If the delta-peak voltage
is not properly detected or the safety timer times out, the
charge process will stop automatically when the battery
reaches the set maximum charge capacity set by the user.
Once you have established the desired settings press
„START/ENTER" to confi rm the setting then press „INC"
to move on to the next parameter.
10
Sound Settings (Key & Buzzer Mute)
A beep sounds to confi rm the every time the user presses a
button, additionally a sound is emitted during the operation
of the charger to confi rm a different mode change. These
functions can be switched on or off. Once you have established
the desired settings press „START/ENTER" to confi rm the
setting then press „INC" to move on to the next parameter.
Low Input Voltage Setting
11
This function monitors the input voltage of the DC power
source used to power the charger. If the voltage is lower
than the user setting, the program will end forcibly to protect
the input source. Once you have established the desired
settings press „START/ENTER" to confi rm the setting. You
have now set the initial user settings. You can repeat this
procedure for the other Channels.