Lamp Configuration; Flair 32/1 Super Power - ergoline FLAIR 32/1 SUPER POWER Instructions De Service

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installed lamps
Num.
Lamp name, starter, filter panels
a)
1
UV high-pressure lamps Ergoline
ULTRA C-12645
1
Filter panel Ultra Performance
b)
14
UV low-pressure lamps GENESIS
HPR15 FR71-T12-BA-120W
14
Starter 160 W
c)
14
UV low-pressure lamps GENESIS
HPR15 FR78-T12-CA-120W
14
Starter 160 W
c)
4
UV low-pressure lamps GENESIS
HPR15 FR71-T12-CA-120W
4
Starter 160 W
10/2009
1008457-00
7.3

Lamp configuration

CAUTION!
The use of other UV lamps and filter panels voids the operating license!
The UV high-pressure lamps fitted are broadband radiators that can be
operated at different outputs.
7.3.1

FLAIR 32/1 SUPER POWER

Length
71 in
78 in
71 in
Power
Activation
level
400 W
400 W / 0 W
120 W
120 W
120 W
120 W
120 W
120 W
Operating Instructions – 21
Technical data
Order no.
12645-..
1504566-..
1504559-..
1004929-..
1504562-..
1004929-..
1504559-..