Open stacking
If the logs are stacked openly, the wood will burn
quickly as the oxygen can reach each log easily. If
you want to use the stove for a short while, make an
open stack.
Compact stacking
If the logs are stacked tightly, the wood will burn more
slowly as the oxygen can only reach some logs eas-
ily. If you want to burn wood for a longer period, make
a compact stack.
4. Close the door of the appliance.
5. Close the primary air inlet and leave the secondary
air inlet open.
Do not fill the appliance by more than a third.
14

Controlling combustion air

The appliance has various features for air control; see
next figure.
2
1
The primary air regulates the air under the stove base
(1).
The secondary air regulates the air for the glass (air
wash) (2).
The secondary air has vents (3) above the grate that
allow for afterburning.
The appliance has one air control system that reg-
ulates both the primary air and the secondary air. If the
air control is fully to the right, the primary and the sec-
ondary air inlet are open. As the air slide is pushed
more to the left, this closes off the primary air inlet and
then the secondary air inlet. If the air slide is com-
pletely closed, a small air vent remains open to allow
for the afterburning; see following figure.