Les langues disponibles

H05RR-F 4x4 CEI-UNEL 35363
GB
H05VV-F 4x4 CEI-UNEL 35746
H05RR-F 5x2.5 CEI-UNEL 35363
H05VV-F 5x2.5 CEI-UNEL 35746
• Secure the power supply cable by fastening the
cable clamp screw then put the cover back on.
Connecting the supply cable to the electricity mains
Install a standardised plug corresponding to the load
indicated on the appliance data plate (see Technical
data table).
The appliance must be directly connected to the mains
using an omnipolar switch with a minimum contact
opening of 3 mm installed between the appliance and
the mains. The switch must be suitable for the charge
indicated and must comply with current electrical
regulations (the earthing wire must not be interrupted
by the switch). The supply cable must be positioned
so that it does not come into contact with temperatures
higher than 50°C at any point.
Before connecting the appliance to the power supply,
make sure that:
• The appliance is earthed and the plug is compliant with
the law.
• The socket can withstand the maximum power of the
appliance, which is indicated by the data plate.
• The voltage falls between the values indicated on
the data plate.
• The socket is compatible with the plug of the
appliance. If the socket is incompatible with the
plug, ask an authorised technician to replace it. Do
not use extension cords or multiple sockets.
! Once the appliance has been installed, the power
supply cable and the electrical socket must be easily
accessible.
! The cable must not be bent or compressed.
! The cable must be checked regularly and replaced
by authorised technicians only.
! The manufacturer declines any liability should
these safety measures not be observed.
Data plate, is located inside the flap or, after the oven
compartment has been opened, on the left-hand wall
inside the oven.
24
400V 2N~
N
L2 L1
400V 3N~
N
L3
L2
L1
Safety Chain
supplied safety chain MUST be installed!
The cooker is fitted with a safety chain to be fixed by
means of a screw (not supplied with the cooker) to
the wall behind the appliance, at the same height as
the chain is attached to the appliance.
Choose the screw and the screw anchor according
to the type of material of the wall behind the applian-
ce. If the head of the screw has a diameter smaller
than 9mm, a washer should be used. Concrete wall
requires the screw of at least 8mm of diameter, and
60mm of length.
Ensure that the chain is fixed to the rear wall of the
cooker and to the wall, as shown in figure, so that
TABLE OF CHARACTERISTICS
Oven dimensions
32,4x43.5x40,3 cm
(HxWxD)
57 l
Volume
Useful
width 42 cm
measurements
depth 44 cm
relating to the oven
height 8.5 cm
compartment
Voltage and
see data plate
frequency
Regulation (EU) No 65/2014 supplemen-
Regulation (EU) No 65/2014 supplemen-
ting Directive 2010/30/EU.
ting Directive 2010/30/EU.
Regulation (EU) No 66/2014 implementing
Regulation (EU) No 66/2014 implementing
Directive 2009/125/EC.
Directive 2009/125/EC.
Standard EN 60350-1
Standard EN 60350-1
Standard EN 50564.
Standard EN 50564.
Standard EN 60350-2.
Energy consumption for Natural
convection – heating mode:
Convection mode
ENERGY LABEL
Declared energy consumption for
Forced convection Class – heating
mode:
Roasting
EC Directives: 2006/95/EC dated
12.12.06 (Low Voltage) and subsequent
amendments - 04/108/EC dated
15/12/04 (Electromagnetic
Compatibility) and subsequent
amendments - 90/369/EEC dated
29/06/90 (Gas) and subsequent
amendments - 93/68/EEC dated
22/07/93 and subsequent amendments
- 2002/96/EC.
1275/2008 (Stand-by/Off mode)
! In order
to prevent
accidental
tipping of the
appliance, for
example by
a child clim-
bing onto the
oven door, the

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ci 96i a sCi 96i w sCi 96i k sCi 66 v w sCi 66 v i sCi 66 v a s