04.08.4 Anti-calc function

Please do not
open the filling
opening during
steam bath!
For safety, we
recommend to
wait at least 30
minutes after
the end of steam
bath to cool the
cabin.
With the menu item
"Decalcifying" in the
service settings, you can
start the decalcifying process manually at any time. There you
select the buttons
and
if you want to decalcify the device
at this time or not and confi rm with [OK] button.
250 ml of a descaling liquid (e.g. HOESCH special descaler, no.
692101) should be used for decalcifying.
Anti-calc function
After 20 hours of work the device automatically calls for anti-calc
function start up. The following message appears in the display:
Do you want to start anti-calc function?
You can select "Yes" to start the anti-calc process or "No" to start
this function just after the steam bath. Before starting the next
steam bath the anti-calc process must be started, otherwise, the
system will not allow to start the steam function indicating the
necessity to run the anti-calc function.
Manual decalcification
Please, enter "Service" subsection choosing menu and then press
the "anti-calc" button and select "menu".
Pressing the
and
button, you can choose if you want to
start decalcifi cation process and confi rm it with [OK] button.
04.09 Manual instruction of the fi xtures
A
1
B
2
Faucet knobs
,
devide water stream to chosen outlets.
1
3
The knobs serve to open and close the water and regulate water
presure.
– hand shower on
1
– showerhead on
2
– Kneipp hose on
3
Faucet knob
serves to set temperature. Turning without
2
pushing the control button regulates water temperature in range
up to 38°C (burn protection function)
Turning with the control button pushed regulates water
temperature in range over the 38°C
Regarding the possibility of burning it is recommend to use
temperature up to 42°C.
The calibration of thermostatic valve in case of faulty temperature
regulatio should be done at 38°C based on the following
indications:
start manual shower funktion setting the knob at 38°C
measure the water temperature with the normal thermometer
mark with a line 38°C temperature inthe panel as marked in
the shower knob
push the red button and slowly turn the knob until 38°C
temperature of water stream is reached
take the cap off, unscrew the bolt and pull out the knob
install the knob in a way that the panel is in the same place as
38°C temperature mark in the knob
screw the bolt and put the cap
3
In order to remain entitled to repairs under the guarantee and to
keep the shower panel looking good, you should do the following:
remove sediment and impurities regularly from the screen.