Diagnostics
Consequences
Actions
Photoelectric
cells
Diagnostics
Consequences
Actions
Diagnostics
Consequences
Actions
Radio
Diagnostics
Diagnostics
Command
Consequences
Actions
14.2 XSE transmitter
> Problem on XSE transmitter
LED1 and LED2:
/
Step 1: CHECK THE BATTERY
Remove the battery then press a button (PROG or MODE) to discharge
test is under way - it may last up to 2 minutes).
- If LED1 and LED2 light up red for 5 seconds, replace the battery and repeat
the operations above.
- If LED1 and LED2 light up green for 5 seconds, skip to step 2.
Step 2: CHECK THE OPERATION OF THE SAFETY EDGE
Press and hold the MODE button for 3 seconds to launch safety edge
detection.
- If LED2 lights up green then the safety edge and transmitter are operating
correctly. Squeeze the safety edge and check that LED2 lights up red.
- If not, go to step 3.
16
Indicator light status
Cell fault
Opening ok
Closing by pressing and holding down
the button within sight of the door
If no cells are installed, check that the
connector (terminals 18 and 19) is
bridged.
If cells are installed:
- Check that no obstacle is cutting across
the cell beam
- Check the position of dipswitch no.2
according to the type of cell (see
section 7.2).
- Check the cell wiring (see section 7.3).
Bridged cell connector
Opening ok
Closing by pressing and holding down
the button within sight of the door
If no cells are installed and cell connectors
are bridged (terminals 18 and 19), check
that dipswitch no.1 is set to OFF.
Obstacle detection
Remove the obstacle by full automatic
opening
Check that no obstacle is cutting across
the cell beam.
Radio frame received from a recognised
transmitter
When a key on the keypad or a remote
control button is pressed, the indicator
The product works but the keypad or
remote control cannot be used (depending
on the position of dipswitch 5) to control it.
Deactivate holiday mode (see section 8.4).
/
Step 3: DETERMINE THE ORIGIN OF THE FAULT: XSE TRANSMITTER
OR SAFETY EDGE?
Prog
Disconnect the safety edge.
Test 1: Press and hold the MODE button for 3 seconds to launch safety
edge detection.
-
correctly.
- If not, the XSE transmitter is faulty.
Test 2 (optional): Press and hold the MODE button for 3 seconds to launch
safety edge detection by short-circuiting the 2 contacts on the ESE J3
- If LED2 lights up red for 8 seconds then the XSE transmitter is operating
correctly.
- If not, the XSE transmitter is faulty.
If tests 1 and 2 show that the transmitter is operating correctly, replace
the safety edge.
> Problem waking up the transmitter at the Up point
Important: For each test, wait until LED2 goes off to test that the transmitter
wakes up.
Test 1: Check that the XSE transmitter is working by tapping it and check that
LED2 lights up green. If not, press and hold the PROG button for 3 seconds
and retest. If the problem persists, replace the XSE transmitter.
Test 2:
dipswitch 3 is ON, then retest.
Test 3:
XSE transmitter to ON then retest.
If the problem persists, replace the XSE transmitter.
15 - TECHNICAL DATA
Power supply
Electrical insulation
Maximum motor output
Safety fuse for motor and integrated
lighting
Climatic operating conditions
Somfy radio frequency
Number of storable remote controls
CONNECTIONS
Mains power supply cable
Integrated courtesy lighting
Safety inputs
Self-test output for safety devices
Wired control input
Orange light
Alarm siren output
OPERATION
Control buttons
Automatic closing mode
Maintenance assistance
230 V - 50-60 Hz
Category 1
230 V - 1250 W
5 AT - 250 V - spare fuse supplied
- 20°C/+ 60°C - IP 20
io 868 - 870 MHz
< 25 mW
30
2 m - IEC sheet (phase-neutral-earth)
E14 - 1.4W - 230V LED bulb
3 inputs for:
- Wired safety edge: optical, resistive
- Fall protection device
- Photoelectric cells
For cells
NO dry contact - sequential operation
24V - 4W max.
Yes
Up-Stop-Down buttons in the control
panel
Yes
Real time status with 5 indicator lights
Copyright © 2014 SOMFY ACTIVITES SA. All rights reserved.