Before each fault elimination:
− switch off device
− Wait for the power pruner to come to a standstill
− Pull out power plug
After each fault clearance, put into operation and recheck all security installations.
Fault
Power pruner does not
start after switching on
Power pruner works
with interruptions
Power pruner picks,
vibrates or does not
saw correctly
Power pruner does not
work with full power
Saw chain gets hot
No
saw
chain
lubrication
Typ / Model
Year of construction
Motor rating P
1
Mains voltage
Mains frequency
Mains fuse
No-load speed of the sprocket
Saw chain speed
Oil tank volume max.
Protection class
Saw chain
Guide bar
Cutting length
Measured sound power level L
Guaranteed sound power level L
Measuring uncertainty K
WA
Sound pressure level L
PA
Measuring uncertainty K
PA
Hand arm vibration a
vhw
Measuring uncertainty K
Weight without cutting assembly and with empty oil tank
24
Possible cause
no power
Extension cable damaged
Mains plug, motor or switch defect
external loose connection
internal loose connection
ON / OFF switch defective.
Chain edgeless
Chain worn
Chain tension
Chain not assembled correctly (teeth
face to wrong direction)
Extension cable too long, or cross-
section too small.
Socket too far from mains supply.
no oil in the tank
oil flow canal blocked
chain tension too high
Chain edgeless
no oil in the tank
oil flow canal blocked
WA
WA
Possible faults
Remedy
Check power supply, power outlet, fuse protection
Check extension cable,
immediately
Have motor or switch checked by an approved electrician
or replaced by original spare parts
Contact the customer service
Chain must be regrinded or exchanged
Exchange chain
Check and adjust chain tension
Assemble chain again
Only use extension cables with sufficient core cross-
section.
Use power outlet which is nearer within the working area
Refill oil
Clean oil flow canal
Adjust chain tension
Chain must be regrinded or exchanged
Refill oil
Clean oil flow canal
Technical data
KSH 710 SDS
see last page
710 W
230 V
50 Hz
10 A inert
8300 min
-1
13 m/s
150 ml
ΙΙ /
90JG033X, alternative 90PX033X (3/8 " – 1.1 – 33)
084LNE A041 203 mm (8'')
180 mm
101.9 dB (A) (measured according to regulation 2000/14/EC)
103 dB (A) (measured according to regulation 2000/14/EC)
0.31 dB (A)
83 dB (A) (accordingto regulation 2000/14/EC)
3.0 dB (A)
3.64 m/s
2
1.5 m/s²
approx. 4.5 kg
exchange defect
cable