11. Troubleshooting
Having trouble?
Noise is louder than specifications.
Nothing appears in the wireless remote controller display, the display
is faint, or signals are not received by the indoor unit unless the remote
controller is close.
The operation lamp near the receiver for the wireless remote controller
on the indoor unit is flashing.
Warm air blows from the indoor unit intermittently when heat mode is off
or during fan mode.
Range of application
The range of working temperatures for both the indoor and outdoor units of the series Y, R2, Multi-S is as below.
Caution:
The use of your air conditioner outside the range of working temperature and humidity can result in serious failure.
Mode
Indoor unit
Cooling
15 °C - 24 °C WB
Heating
15 °C - 27 °C DB
Note: As an applicable humidity standard for both indoors and outdoors, we recommend use within a range of 30 - 80% relative humidity.
Warning:
If the air conditioner operates but does not cool or heat (depending on model) the room, consult your dealer since there may be a
refrigerant leak. Be sure to ask the service representative whether there is refrigerant leakage or not when repairs are carried out.
The refrigerant charged in the air conditioner is safe. Refrigerant normally does not leak, however, if refrigerant gas leaks indoors, and
comes into contact with the fire of a fan heater, space heater, stove, etc., harmful substances will be generated.
12. Specifications
Model
Power source (Voltage<V>/Frequency)
Capacity (Cooling/Heating)
Dimension (Height)
Dimension (Width)
Dimension (Depth)
Net weight
Fan Airflow volume (Low-High)
Noise level (Low-High)
Model
Power source (Voltage<V>/Frequency)
Capacity (Cooling/Heating)
Dimension (Height)
Dimension (Width)
Dimension (Depth)
Net weight
Fan Airflow volume (Low-Middle-High)
Noise level (Low-Middle-High)
*1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.
Cooling: Indoor 27 °C DB/19 °C WB, Outdoor 35 °C DB
Heating: Indoor 20 °C DB, Outdoor 7 °C DB/6 °C WB
*2 This figure ( ) indicates panel's.
The indoor operation sound level is affected by the acoustics of the
particular room as shown in the following table and will be higher than
the noise specification, which was measured in an echo-free room.
Location
examples
Noise levels
The batteries are low.
Replace the batteries and press the Reset button.
If nothing appears even after the batteries are replaced, make sure
that the batteries are installed in the correct directions (+, –).
The self diagnosis function has operated to protect the air conditioner.
Do not attempt to repair this equipment by yourself.
Turn off the power switch immediately and consult your dealer. Be
sure to provide the dealer with the model name.
When another indoor unit is operating in heat mode, the control
valve opens and closes occasionally to maintain stability in the air
conditioning system. This operation will stop after a while.
* If this will cause an undesirable rise in the room temperature in
Outdoor unit
PUHY
–5 °C - 43 °C DB
–5 °C - 43 °C DB
–15 °C - 15.5 °C WB
–12 °C - 15 °C WB
PKFY-P63VKM-E
<Hz>
<kW>
<mm>
<mm>
<mm>
<kg>
3
<m
/min>
<dB>
PLFY-P20VCM-E2
<Hz>
<kW>
2.2/2.5
<mm>
<mm>
<mm>
<kg>
<m
3
/min>
<dB>
28-31-35
Here is the solution. (Unit is operating normally.)
High sound-
Normal rooms
absorbing rooms
Broadcasting
Reception room,
studio, music
hotel lobby, etc.
room, etc.
3 to 7 dB
small rooms, etc., stop the operation of the indoor unit temporarily.
PURY
PUMY
–5 °C - 46 °C DB
–12 °C - 15.5 °C WB
~N/220-230-240/50, 220-60
7.1/8.0
365
1170
295
22
16-20
39-43
PLFY-P25VCM-E2
PLFY-P32VCM-E2
~N/220-230-240/50
2.8/3.2
3.6/4.0
208 (20)
570 (650)
570 (650)
15.5 (3)
8-9-10
28-31-37
29-33-38
Low sound-
absorbing rooms
Office, hotel
room
6 to 10 dB
9 to 13 dB
PKFY-P100VKM-E
11.2/12.5
20-25
41-49
PLFY-P40VCM-E2
4.5/5.0
17.0 (3)
8-9-11
30-34-39
19