Items supplied
1 Power tool, 1 Chuck TE-C CLICK, 1 Side handle with depth gauge, 1 Operating instructions, 1 Hilti toolbox (option),
1 Cleaning cloth (option), 1 Grease (option)
Technical data
Voltage
Weight as per EPTA-Procedure 01/2003
en
TE 6-A including belt adaptor (without battery)
Dimensions (L×H×W)
Speed
Hammering speed
Single impact energy
Chuck
Drill bit dia. range in concrete
Drill bit dia. range in wood
Drill bit dia. range in metal
Dust-tight encapsulation and permanent lubrication (maintenance-free)
NOTE
The vibration emission level given in this information sheet has been measured in accordance with a standardised
test given in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary asses-
sment of exposure. The declared vibration emission level represents the main applications of the tool. However if
the tool is used for different applications, with different accessories or poorly maintained, the vibration emission
may differ. This may significantly increase the exposure level over the total working period. An estimation of the
level of exposure to vibration should also take into account the times when the tool is switched off or when it is
running but not actually doing the job. This may significantly reduce the exposure level over the total working peri-
od. Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the
tool and the accessories, keep the hands warm, organisation of work patterns.
Noise and vibration information
(according to EN 60745)
Typical A-weighted sound power level
Typical A-weighted emission sound pressure level
For the given sound power level as per EN 60745, the tolerance is 3 dB.
Wear ear protection!
Triaxial vibration value (vibration vector sum)
measured in accordance with EN 60745-2-1 prAA: 2005
Drilling in metal, (a
measured in accordance with EN 60745-2-6 prAB: 2005
Hammer drilling in concrete, (a
Uncertainty (K) for triaxial vibration value
Technical data for the battery
(accessory TE 6-A)
Voltage
Battery capacity
Weight
Type of cell
No. of cells
Temperature monitoring
Deep discharge prevention
12
Printed: 07.07.2013 | Doc-Nr: PUB / 5071061 / 000 / 00
)
h, D
)
h, HD
BP 6-86
36 V
36 V x 2.4 Ah
= 86.4 Wh
2.1 kg
Nickel-
cadmium
30
NTC
36 V
5.0 kg (TE 6-A)
4.0 kg (TE 6-A Li)
2.8 kg
330×225×100 mm (TE 6-A)
330×215× 90 mm (TE 6-A Li)
890 r.p.m.
5,000 blows/min.
1.5 joules
TE-C Click
up to 16 mm
up to 20 mm
up to 10 mm
TE 6-A
TE 6-A Li
101 dB(A)
101 dB(A)
90 dB(A)
90 dB(A)
1.5 m/s
2
2.5 m/s
11.0 m/s
2
10.5 m/s
1.5 m/s
2
1.5 m/s
B36 / 2.4 NiCd
36 V
36 V x 2.4 Ah
= 86.4 Wh
2.08 kg
Nickel-
cadmium
30
0
NTC
2
2
2