Installation
Note: As the cooking of food is made through infrared radiation, the surrounding
temperature in front of the rotisserie may be quite high. This is the reason why you should
not place the side walls of your rotisserie along a wall made of combustible material, except
if the wall is covered with a good temperature insulation. You should keep 1 foot space
between the rotisserie and the wall.
Electrical connection
The appliance must be installed in accordance with current regulations by professional
people.
Before connecting your appliance, check the voltage and currents your main supply can
bear.
The rotisseries RBE 80 have to be plugged on 400 V 3 phases + neutral or 230 V single
phase (in that case the cord dimension must be upper than 4 mm2).
The rotisseries RBE 120 and RBE 200 have to be plugged on 400 V 3 phases + neutral or
230 V single phase (in that case the cord dimension for RBE 120 must be upper than 6 mm2
and for RBE 200 upper than 9 mm2).