Construction

5
Construction
5.1

Mechanical construction

The rotor disc is located at the end of the rotor shaft with double ball bearings and is
driven via a flexible coupling by a DC motor.
Product feed is effected via a dispensing needle which runs parallel to the rotor shaft; the
connection for product is integrated in the headpiece of the rotor sprays. Alternatively, the
dispensing valve can be attached directly to the rotor spray via the angle bracket available
as an accessory.
Speed adjustment is carried out at an adjustment ring at the end of the rotor spray.
The voltage supply and signal exchange are via an 8-pole connector.
Fig. 2: Rotorspray integra
Fig. 3: Rotorspray integra
5.2

Electrical construction

The electrical construction comprises the drive motor, a control board with speed regulator
and power circuitry as well as the 8-pole connector M12.