SOMFY ELIXO 2000 230v rts Manuel D'installation page 19

Motorisation destinée à l'équipement d'un portail coulissant
Masquer les pouces Voir aussi pour ELIXO 2000 230v rts:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ELIXO 2000 230V RTS
Menu
Sub-menu
1
2
0
1
0
1
0
1
0
1
0
1
2
3
4
5
6
7
1
(auxiliary 3)
2
Copyright
©
2018 SOMFY ACTIVITES SA. All rights reserved.
Val.
Semi-automatic
• pressing the button on the remote control while the gate is open-
ing will stop the gate
• pressing a button on the remote control during closing causes it
to reopen
Automatic
In automatic mode, the final position of the gate will always be the
closed position.
Operation in automatic closing mode is only authorised if photoelec-
tric cells with autotest function are installed (see Fig. 19).
• the gate closes automatically a er the timeout programmed in the
/
menu
• pressing the button on the remote control during opening has no
effect,
• pressing a button on the remote control during closing causes it
to reopen
• if an obstacle is located within the detection zone of the cells
during the timeout, the timeout is reinitialised once the cells are
cleared
Automatic + cell blocking
During and a er gate opening, movement in front of the cells (safe
closure) will close the gate a er a short timeout (fixed at 3 seconds).
If there is no movement in front of the cells, the gate will close
automatically a er the closing timeout programmed in the
/
menu.
Not used
Without notice before movement
With 3 s warning prior to movement
Pulse-controlled operation
"Dead man" operation
• Input 19 configured as OPEN UP
• Input 20 configured as CLOSED UP
Controlled by maintained action
Pulse of radio-configured inputs takes effect during opening
Pulse of radio-configured inputs does not take effect during opening
Pulse of radio-configured inputs takes effect during TCA opening
Pulse of radio-configured inputs does not take effect during TCA pause
Gate opens towards the right
Gate opens towards the le
Cell safety input active without autotest during opening only
Cell safety input active with autotest during opening only
Cell safety input active without autotest during closing only
Cell safety input active with autotest during closing only
Safety edge safety input active without autotest
Safety edge safety input active with autotest
Gate open indicator light output
Contact closed when opening and when the gate is open, intermittent during closing, open with gate closed
Courtesy lighting command output
Contact closed for 90 seconds a er the last movement
Control unit reset to factory configuration
Default value
Gate travel auto-programming started
Control unit so ware version
Number of cycles (per hundreds)
Description
Attention
Safety devices inactive
Attention
Do not modify the display language on the interface.
In the installation manual, the names of the menus and sub-menus
are in English only.
With following
parameter
setting:
= 0
= 0
= 0
With following
parameter
setting:
= 1
= 1
= 1
With following
parameter
setting:
= 1
= 1
= 1
=1
EN
8