Installation - Flotec FP5712-02 Notice D'utilisation

Pompe de surpression réparable
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation

INSPECT THE SHIPMENT
The high pressure booster pump has been carefully
inspected and packaged to assure safe delivery. Inspect the
pump and fittings and report to the carrier any items
which are damaged or missing.
TABLE I - DISCHARGE PRESSURE
No. of
Model
HP
Stages
FP5712-02
1/2
6
FP5722-02
3/4
8
FP5732-02
1
10
NOTE: For total discharge pressure, add this pressure to
suction pipe pressure. For example, an FP5712-01 pump
taking suction from a 100 psi water service line will pro-
duce 75 + 100 = 175 psi total discharge pressure at 0
GPM flow. If suction pressure drops to 50 psi, discharge
pressure will drop to 125 psi.
INSTALLATION
The pump is designed to boost city water pressure or
water pressure from a private water system. Use this high
pressure stream to wash down milk parlors, barns, garages
and driveways, or for fire protection.
The pump is portable with a convenient carrying handle. If
an existing pressure water system is to be used as a water
supply, it can be connected with available fittings and 3/4"
or 1" high pressure hose to the pump inlet. A special heavy
duty 3/4" or 1" suction hose with fittings is available as an
accessory. If pump is permanently mounted on wall, use a
3/4" or 1" pipe or heavy-duty hose for suction line. This
pump can be disassembled for service without removing
installation piping.
Hazardous pressure. Pump body may
explode if pressures exceed rated limits. Maximum inlet
pressure is 80 PSI. Maximum discharge pressure is 315
PSI. Warranty is void if these pressure limits are exceeded.
For parts or assistance, call Flotec Customer Service at
Discharge
Discharge
Pressure at
Pressure at
Rated Flow
No Flow
75
113
97
147
134
188
HIGH PRESSURE BOOSTER PUMP
INSTALLATION INSTRUCTIONS
These instructions cover high pressure booster pump
installations as shown below:
From pressurized
house service
Figure 1 – Connection to house service.
Water tank
or reservoir
Figure 2 – Connection to water reservoir.
1-800-365-6832
Suction
Discharge
1208 0505
Suction
Discharge
1207 0505
4

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Fp5722-02Fp5732-02

Table des Matières