EN
Problem
Possible cause
Only mode indicator LED
Battery voltage is too low
'inverter on' blinks red
(<10V).
once per second.
Problem
Possible cause
Only mode indicator LED
Inverter is overloaded.
'inverter on' blinks red
twice per second.
Connected AC output load causes a short circuit.
Connected AC output load
causes a too large inrush current.
Problem
Possible cause
Mode indicator LEDs
The Inverter Charger Combi has shut down
'inverter on' and
due to a too high temperature.
'charger on' are blinking
red three times per
second.
Problem
Possible cause
Mode indicator LED 'AC
AC input signal is present but not within required
in' blinks red once per
voltage and frequency borders.
second.
Problem
Possible cause
All mode indicator LEDs
Maximum AC transfer switch current has been
'inverter on' , 'charger on'
exceeded.
and 'Line' are blinking
red twice per second
(manual restart needed)
Problem
Possible cause
Output power bar is red
The inverter is overloaded and will shut down after a
(inverter mode).
certain time (depending on the amount of overload)
Problem
Possible cause
All mode indicator LEDs
Device or connection fault.
'inverter on' , 'charger on'
and 'Line' are blinking
red four times.
13
Remedy
Apply mains voltage to the AC input and start
charging the battery.
Remedy
Make sure that the total power rating of the AC output
load is lower than the nominal inverter power rating.
Make sure that the AC output load is not defective.
Check if the AC output wiring and connections are
not creating a short circuit.
Try to power-up connected equipment successively,
and not simultaneously. Otherwise stop using the
connected load, it's not suitable to power it with this
inverter.
Remedy
Reduce the AC output load in inverter mode.
Try to reduce the ambient temperature around the
Inverter Charger Combi. Make sure that there is a
clearance of at least 10cm around the unit. Do not
obstruct the airflow, place no items on or over the
unit. Keep the Inverter Charger Combi away from
direct sunlight or heat producing equipment.
Remedy
Make sure that the AC input voltage falls within
185V – 270V and 45Hz – 65Hz.
Remedy
Reduce the AC output load
Remedy
Reduce the AC output load.
Remedy
Inverter Charger Combi is defective, return for
service. External AC source is connected to the
AC output instead of the AC input.

Publicité