Venting The Compressor System; Cleaning Work; Checking Of Oil Level - MIL'S AM 3 Notice D'utilisation

Compresseurs à vis
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

 
 
5.4.
Venting the compressor system 
 
Observe the following when the unit has to be vented. 
 
There is a danger of being burned when unit is at operating temperature.
 
The oil refill plug can reach temperatures  
of up to 110°C! Therefore, only handle oil refill plugs with safety gloves! 
 
When removing the oil refill plug, residual pressure may cause hot oil to squirt out. Therefore, 
always wear safety glasses! 
 
Venting the installation 
Observe the following safety instructions to avoid damage to health or danger of life: 
 
Step 
Activity 
Switch off unit and prevent it from being restarted by accident. 
Unscrew cap of oil refill port (oil refill plug) by hand.  
Proceed slowly for the first five turns of the cap. Unscrew in an anticlockwise direction until you can 
hear it "snap"; the oil refill plug has its own safety relief hole on the side, which allows residual 
pressure to escape gradually.  
Wait until all of the pressure of the unit has been released via the safety relief hole. The unit is now 
pressureless.  
5.5.
Cleaning work 
 
For general cleaning work, vacuum the unit and/or wipe it with a damp cloth. Regularly check the intake 
passage and where necessary remove any leaves, dust, dirt or similar to ensure a perfect air supply.    
 
Never direct compressed air at a living being.  
Misuse of the compressed air unit can cause tissue damage or fatal injury.  
 
520513.01 
 
AM3 – AM55 
Replace the air filter 
Step
Activity
1
Switch off unit and prevent it from being restarted by accident. 
2
Unscrew screw on the filter cover and remove the cover. 
3
Remove filter cartridge. 
4
Wipe away dust from the filter housing (inside and outside) using a lightly damp cloth.  
5
Replace the cartridge
6
Place new cartridge in housing.
7
Fit the filter cover and retighten screw, making sure the cover is fitted correctly. 
8
Carry out test run and check functioning.
5.5.1. Checking of oil level 
The oil level in the oil reclaimed reservoir is an important factor in ensuring that the unit is operationally safe. 
Carry out the checks described below thoroughly and to the specified schedule. 
Otherwise, we cannot assume liability for any damages which may occur. 
 
Observe the safety instructions concerning the venting of the unit see chapter 5.4
 
 
 
 
 
 
 