LUBRICATED VACUUM PUMP K04‐K08‐K12 
 
Storage 
Drain the pump of oil inside and close the intake and outlet with the appropriate protections. The pumps are to be stored 
in their packaging and stored in covered, dry, protected places that are not exposed to bright sunlight, with temperatures 
in the range indicated in the table of technical specifications. 
In  case  of  long  periods  of  stop  inside  the  warehouse  or  out  of  production  with  storage,  the  location  should  meet  the 
specifications described in Chapter 3 (Pump description). In order to keep rubber parts and lip seals efficient and properly 
working, we recommend operating the pump for at least 30 minutes every 6 months with the intake closed, following the 
instructions and provisions described in this manual, paying particular attention to those in Chapter 5 (Use instructions). 
The non‐observance of the provisions could cause the rubber parts to degrade leading to oil leakages during operation. 
 
Environmental conditions 
The  pump  must  be  installed  and  used  in  a  covered  and  adequately  lit  location.  The  installation  area  must  meet  all 
requirements of height, air circulation and meet the requirements imposed by existing legislation. 
Temperature, Humidity and altitude 
The  corresponding  limit  values  are  shown  in  the  table  of  the  technical  specifications  (chapter  3.3).  Please  contact  the 
Manufacturer if environmental conditions are different from those prescribed. 
Lighting 
All areas must be illuminated evenly and sufficiently to ensure all operations included in this manual and must be without 
shadows, reflections, glare or eyestrain. 
 
Pump installation 
To ensure perfect pump operation, house and place it according to the following conditions: 
• Allow sufficient space on the perimeter sides of the pump and make sure to keep the motor ventilation side free. 
• Make  sure  the  free  space  adjacent  to  the  pump  allows  easy  access  to  components  for  inspection  or maintenance 
and also allows access for suitable lifting equipment. 
• The pump is equipped with mounting points. It is necessary to ensure it locks onto a perfectly horizontal plane in order to 
avoid tilting in case of transportation by the system user. 
• Some  models  are  already equipped  with  rubber  vibration  dampers  installed  at  pump  attachment  points. 
Whenever the model has not been equipped, ensure installation of such equipment so as not to transmit vibration to the 
pump. 
• Ensure there is ventilation in the room or inside the machine housing the pump and prevent air coming in from the outlet 
or cooling fans, which could cause discomfort to personnel. 
 
WARNING 
Do not install the pump in any area with dust or other materials that could clog or rapidly cover cooling surfaces.
User system 
Make sure that no harmful substances contaminate the user system during installation. 
If you  wish  the system  to maintain  vacuum  even when  pump  is stopped,  install  a cutoff  valve  between pump and 
system. 
Make sure that no vibrations or stresses are transmitted to the pump connection. 
Cconnexion 
HAZARD 
Pump connections should be performed by skilled and trained personnel only.
 
Intake and outlet connections 
User system connections (both intake and outlet) must be performed with pipes with a diameter equal to or greater than 
the pump suction inlet. The weight of pipes or any expansions must not burden the pump. 
 