Safety valve 
The safety valve is mounted on the oil re‐claimer before the oil separator cartridge. It is set 1‐2 bar above the 
max.gauged pressure. The safety valve blows off in case the final pressure is exceeded due to a fault 
somewhere in the system. 
 
2.1.2. Instrumentation panel 
2.1.3. Instrumentation panel description 
 
Item 
 Description 
 Gauge:  
13 
 service pressure(g) 
 Combistat 
14 
Temperature  indicator:   
15 
 Hour meter 
16 
 Start pushbutton 
 Stop pushbutton
17 
17bis 
 EMERGENCY STOP 
18 
Machine plate 
520513.01 
 
 Function 
 Indication of working pressure 
 Indication of service temperature or overheating 
 Counts the service hours of the compressor
 Switches compressor on 
 For switching the compressor off  
 
 in emergency cases only 
 Shows the main performance data and the compressor model
AM3 – AM55 
 
a : On button
‐Start the installation 
‐Button of acquittal after the breakdowns 
b : State display (LED)
‐The current state is indicated by a continuous or indicating light 
‐ Sleep mode (starting up if necessary) 
‐Off‐load operation phase (pressure attained)    
‐Gradual discontinuation time 
‐Restarting. After a power failure(Watling time 90s) 
c : Off button
‐Gradual discontinuation of the installation 
 
‐Press again the On button to start the installation 
‐If you press Off button during acceleration, the installation stops immediately 
 
Off‐load operation time regulation : 
 
The regulation is obtained with switch SW1 and SW2 position 
 
 
 
 
SW1 
SW2 
 
 
Time 
180 s 
180 s 
240 s 
360 s 