4. TROUBLESHOOTING ADVICE IN CASE OF MALFUNCTIONING 
The followings faults may occur during service: 
 
Incident 
Cause éventuelle
incorrect 
The phases were connected back to 
direction of 
front 
rotation 
Compressor does 
No current 
not start: 
Loose cables or fuses 
Motor protection switch stopped 
compressor 
Combistat stopped compressor / is 
defective 
 
Connecting cables to
Combistat are defective
Compressor 
Too long or too short star‐delta switch 
struggles to start 
over time 
Compressor is under pressure 
 
Fluctuations in the power system 
Temperature of the site is too low and 
therefore the oil is too viscous 
Oil is too viscous
compressor stops 
Motor overload has tripped 
before reaching 
 
final pressure 
 
 
Combistat switches off due to high 
temperature 
Control current is short‐circuited 
Motor overload 
Machine bloquée 
stops the 
Défaillance des phases 
compressor 
Surcharge du moteur 
 
 
Température ambiante trop élevée 
Combistat 
Shortage of oil 
operates due to 
Oil filter clogged 
high temperature 
Defective thermostat 
Dirty oil cooler 
Incorrect installation of compressor 
Faulty Combistat or incorrectly set 
520513.01 
 
Dépannage
Change the connections of 2 electric 
lines 
Make current available
Retighten cables and fuses 
Unlock motor‐protection switch (in 
electric control panel) 
Ensure correct cooling, change 
Combistat when defective 
Ensure  correctly fed connecting 
 
 
cables
Check and reset time period, correct 
setting is 3‐6 seconds on relay K1T 
Check/change solenoid valve / vent 
the compressor 
Determine reason 
 
Heat site and
compressor or position 
in warmer area 
  
Choose suitable oil
Check overload setting and if 
necessary alter it. Check setting of 
pressure switch, if necessary, alter it. 
Check supply of all three phases. 
Ensure correct cooling; change 
Combistat if necessary. 
Remove reason for short‐circuit 
and/or replace fuses 
Remove reason for seizure
Check supply 
Check setting of overload, alter if 
necessary, check/alter settings of 
pressure switch 
Ventilate compressor room 
Check and correct oil level
Change oil filter 
Change thermostat 
Clean cooler (oil and air sides) 
Check installation instructions 
Adjust or replace Combistat 
AM3 – AM55 
Incident 
Cause éventuelle
Safety valve 
Faulty safety valve 
blows 
Oil separator cartridge clogged 
Oil carryover 
Dirty oil return (scavenge) pipe 
Faulty separator cartridge 
High oil level in tank 
Compressor was stopped before end 
of run‐on time (min 3 minutes) 
Compressor does 
Setting of pressure switch too high 
not vent when 
Faulty solenoid 
idling; does not 
Defective relief valve in suction 
stop during 
regulator 
on/off operation 
Minimum pressure valve jams 
i.e. safety valve 
blows off 
Unit continuously
Defective solenoid valve 
pressure relieves, 
Defective relief valve in suction 
reduced flow 
regulator 
Electrical connection to solenoid 
broken 
Faulty auxiliary contact on Y‐contactor 
No capacity or 
Air filter clogged 
reduced flow 
Intake valve faulty or jams 
 
air leaks 
Suction regulator 
Setting cylinder defective, no control 
does not close at 
air 
final pressure 
Jet is blocked, frozen up 
Oil reservoir is 
Non return valve is faulty 
under pressure 
Oil contamination 
Loose connections in oil circulation 
inside cabinet, oil 
system 
mist on venting 
Check seal on oil drain plug 
Compressor stops under pressure 
 
Check condition of O‐ring seal at 
intake valve and its  correct seat 
Compressor runs 
Drive belt not correctly tightened 
noisily 
Drive‐belts are not compatible 
matched sets 
Pulley discs are not aligned 
 
Dépannage
 Change safety valve
 Change separator cartridge 
 Clean scavenge system 
 Check/change separator cartridge 
 Reduce oil level  
 Ensure the compressor is only  stopped 
after run‐on time has elapsed 
 Lower setting of pressure switch 
 Change solenoid valve 
 Check/change relief valve 
 
 Check/correct minimum pressure valve 
 Change solenoid valve 
 Change relief valve 
 
 Rectify electrical connection 
 
 Check / change switch 
 Change air filter cartridge 
 Check suction regulator, butterfly valve, 
clean bearing and guide 
 rectify leak 
 Change setting cylinder and/or solenoid 
valve 
 Clean jet 
 Change non return valve 
 Tighten connections
 
 Tighten screw / replace seal 
 Switch off compressor after 3 minutes 
run‐on time. Check if run‐on time is 3 
minutes or greater 
 Change o‐ring if necessary 
 Check /adjust tension of drive belt 
 Change to compatible matched sets 
 Check and correct alignment of drive 