3.3.
Putting into service 
Before putting the unit into operation for the first time, you must observe the following: 
 
  Step 
 Activity 
 Have all bolted and terminal connections in the switch cabinet been checked for tightness by an 
electrician 
The motor bearings of compressors, without permanent greased motor bearings, that are unused 
longer than 6 month have to be regreased before putting into operation 
 For units which are operated remotely, affix a sign to the unit and in a clearly visible location. The 
sign should have the following message:  
 CAUTION: This unit is controlled remotely and can start without warning.  
 
 When controlling the unit remotely, observe safety regulations which safeguard against the unit 
being started while being checked or maintained; Affix an appropriate sign next to the remote 
control switch.  
 In normal operation, do not switch off units under load using the emergency ‐ see  chapter 3.4
 
Check the direction of rotation of the screw compressor when putting the unit into operation for 
the first time, and each time after the electric cabling is changed.   
 
The direction of rotation is anticlockwise, viewed from the front of the compressor.  
The direction of rotation of the V‐belt pulley must be the same as that indicated by the arrow.  
Reconnect the connection cables where necessary (electrician). 
 
CAUTION 
Operation with an incorrect direction of rotation lasting longer than approx. 2 seconds will 
destroy the screw compressor. 
Danger of moving parts if front doors are left open during check. 
 
Control the direction of rotation as follows: 
  Step 
 Activity: 
 Open front door.
 Start compressor by tapping  the green start button:  
Release button immediately  after!  
 Stop the compressor within 2 seconds by pressing the 
red stop button with the other hand.  
520513.01 
 
AM3 – AM55 
Image
 
Carry out a test run. This allows oil to distribute itself in the unit.  
 
Switching off the unit when the shut‐off valve is open can result in foaming of the oil in the separator tank. This 
may result in the following:  
Oil is discharged with the relief air 
Oil in the separator cartridge overflows 
There is oil within the compressed air when restarting the unit. 
This is usually not critical and the unit should return to normal during the course of operation. However, in 
isolated cases, the separator cartridge may need to be replaced.  
 
3.3.1. Test run 
 Step
 Activity:
1
 Open shut‐off valve. Press start button and allow the 
unit to run for max.5 seconds.  
2
 Press stop button. 
 
3
 Repeat steps 1 and 2 again twice. 
 
 
Attention: stop compressor as described only when  testing. When stopping the compressor in 
normal operation kindly see chapter 3.4 "Stop of compressor". 
 
3.3.2. Compressor start up 
 
Danger! 
There are moving parts inside of the compressor housing which can cause serious injuries. 
Therefore never operate the compressor with the cabinet doors removed ! 
 
 
Before starting the compressor please check the following: 
Is the oil level sufficient? 
Has the circuit breaker been switched on? 
Are any existing shut‐off valves opened? 
 
Image
 
 
23 