1. Stand the pump on a firm surface – or – use a rope
attached through the bore hole (6) in the carrying
handle to immerse the pump in a well or shaft.
During automatic operation, ensure that the float
switch (5) can move freely.
2. Connect the power cable into a mains socket.
To adjust the cut-in and cut-out height:
The cut-in height and cut-out height (see Technical Data)
can be adjusted.
7
16
1. Press the cable of the float switch (5) into an opening
6
5

Manual operation

The minimum residual water depth (see Technical Data) is
only achieved in manual mode because the float switch
already switches off the pump before this when in
automatic mode.
7
5
1. Push the float switch (5) onto the float switch lock (7)
2. Stand the pump on a firm surface – or – use a rope
3. Connect the power cable into a mains socket.
The pump remains in constant operation because the float
switch is bypassed.
in the float switch lock (7).
Do not select a cable length that is too long or short to
ensure that the float switch can turn on and off
properly.
The higher the opening of the float switch lock (7), the
higher the cut-in and cut-out height.
The shorter the length of cable between the float
switch (5) and the float switch lock (7), the lower the
cut-in height and the higher the cut-out height.
The cable length between the float switch (5) and the
float switch lock (7) must always be at least 10 cm.
5
with the cable downward.
attached through the bore hole (6) in the carrying
handle to immerse the pump in a well or shaft.