Connection at tank bottom, APT100
Open de the connection at the bottom of the
tank by means of drilling to use this connection
Apply a drill of 20 mm.
6 2
Fitting the connection cover
Clean the inside of the tank before fitting the
connection cover
• Connection cover (2)
Position the connection cover (2) as shown
in the drawing and fit the nut (3).
• Connections
Installed are the inlet connection (4), hose
pillar 38 mm, and the vent connection (5),
hose pillar 19 mm diameter.
The 38 mm hose pillar can be replaced by a
25 mm hose pillar or a blind plug.
Replace the blind plug (7) with a 19 mm
hose pillar if an (extra) inlet connection is
required.
Extraction connection
Replace the blind plug (6) with a hose pil­
lar, 38 mm diameter, if an extraction pipe is
installed
• Sender for fuel level gauge
If desired, remove the cover (8) and install a
sender for the tank level gauge; always ap­
ply the gasket.
vetus® Connection kit for waste water tanks
3
4
6
2
5
Note: Only the ultrasonic level sensor
(SENSORA) can be used!
The tank float for waste water tanks
(WWSENSORA) can NOT be used.
Check the tightness of all connections
before filling the tank
ENGLISH
20 mm
(
3
/
")
4
7
8
N
!
ote
19
110141.01