Specification
Functional specification
Ambient temperature:
Fluid type:
Fluid temperature:
Accuracy:
Degree of protection*:
CTR Electrical specification
Supply voltage (VS):
Current output:
Voltage output:
SR output:
LTR Electrical specification
Output:
Impedance:
Inductance:
Construction material
Flow body:
Internal parts:
Transducer:
Seals:
For Flow and Pressure ratings see model table
5 to 40 °C (41 - 104 °F)
Oils, fuels, water glycol, water oil emulsions
5 to 90 °C (41 - 194 °F) continuous use
15 to 100% of range - 1% of indicated reading
Below 15% fixed accuracy of 1% of 15% of full scale
CTR-SR – IP54 (EN60529)
CTR-mA, CTR-5V, LTR – IP66 (EN60529)
*With cable connected
mA & 5V = 12 - 32 VDC, SR = 7 - 15 VDC
4 - 20 mA, 3 wire, max loop resistance = (VS x 50) - 200 ohms
0 - 5 VDC, current consumption = 10 mA, minimum load 20K ohms
0 - 3 VDC
Frequency - 20 -2000 Hz
3700 Ohm,
1kHz: 1.55H
600/750/800/1500 High tensile Aluminium 2014A T6
15/60/150/300/400 High tensile Aluminium 2011 T6
Aluminium, Steel, Stainless Steel
Body and nut -steel 212A42 electroless nickel plated, Lid and housing - Aluminium 2011 T3
Viton seals as standard EPDM are available - please consult sales office
3