Possible faults
Before each fault elimination:
Switch off device
Wait until the saw comes to a stop
Pull out power plug
After each fault clearance, put into operation and recheck all security installations.
Fault
Machine fails to start after switching on
Jigging does not work
Machine stops while cutting
Burned spots at the cut areas
Saw vibrates
Recuperating mechanism of the jigging device
does not work
Decelaration too slow (time to dead stop >10
sec.)
Technical data
Type
Year of construction
Motor rating P
1
Mains voltage
Mains frequency
No-load speed n
0
Protection class
Mains fuse
Saw blade (carbide tipped saw blade)
Saw blade location hole
Number of teeth
Thickness of splitting wedge
Cut width
max. cutting capacity
Wood length, max.
Wood length, min.
Dimensions (length x breadth x height)
Weight (incl. accessories)
18
Possible cause
Power failure
Extension cable defect
Motor or switch defect
Safety flap not pressed down properly.
Saw blade blunt
Feed is too great
Saw blade blunt
Saw blade is warped
Saw blade not properly mounted
Recuperating spring broken or worn out
Recuperating bolt popped out from its bracket
Motor brake defective
Remedy
Check the fuse.
Check cable, no longer use defect cable
Have motor or switch checked by an approved
electrician or replaced by original spare parts
Press down the safety flap properly.
Replace saw blade or have it sharpend
Allow motor to cool and proceed working with
less pressure
Replace saw blade or have it sharpend
Replace saw blade or have it sharpend
Mount saw blade properly
Replace the recuperating spring
Insert the recuperating bolt in its bracket and
secure it with a cotter pin
Have motor or switch checked by an approved
electrician or replaced by original spare parts
2.2 KW (S2 15 Min – temporary duty 15 minutes)
approx. min. 30 mm to max. 140 mm
1002 x 737 x 1046 mm
Technical modifications reserved!
BWS 400-2
see last page
230 V~
50 Hz
2800 min
–1
IP 54
16 A slow
405 mm
30 mm
32
2.2 mm
3.0 mm
1000 mm
300 mm
38.3 kg