Manual disabling of the detector

It is possible to disable the detector for a 15 min period:
prior to activities likely to produce smoke (sweeping of a
q
dusty room, of a chimney...) and cause unwanted alarm acti-
vation,
to stop alarm in the event of detection of non-dangerous
q
smoke.
In order to disable the detector, press the test key until the 1
beep sounds or until the detector stops its built-in audible
alarm.
The indicator signalling the state of the detector flashes
every 2 sec.
Red signal LED
indicates the state
of the detector
the unit flashes once
Sensor shut down
Other wired
the unit flashes once
inter-connected
every 10 sec.
detectors
After the 15 min disable period has passed, the detector is
automatically reset to normal operation with the detector
state indicator flashes every 10 s.
To leave shut down mode more quickly press the test button for about 10 s
until the alarm sounds (see reaction in the sensor Test chapter).
White
indicator
LED
-
every 2 sec.
-
st
Built-in audible alarm
-
-
39
For the 15 min
disable period,
the detector will not detect
any smoke, nor release any
audible alarm.