Indel B K BASIC Série Mode D'emploi page 32

Masquer les pouces Voir aussi pour K BASIC Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 59
ENGLISH
TIMER OPERATION METHOD: USE
The Minibars of the K series are equipped with a pre-set thermostat located on the back of the refrigerator
(the temperature has already been adjusted to the correct operating levels). You can select the dura-
tion of the cooling cycles using the remote control. When the Minibar is connected to power supply, it
automatically turns on using the mechanical thermostat functions.
Operating cycles of K compressor unit controlled by the electronic timer
The compressor is in operation to cool
the contents of Minibar and to
ON
freeze the eutectic plate (6 hours
over 24 hour are sufficient).
Preset programs for K version, in which a panel can be installed on the door
PROGRAM
P1
P2
P3
P4
OFF
Preset programs for K version with glass door
PROGRAM
P1
P2
P3
P4
OFF
30
WORKING TIME
1ST CYCLE
09-12
09-13
09-13
WORKING TIME
1ST CYCLE
09-14
08-14
07-14
K BASIC - K SMART - K ECOSMART
The compressor is Off and the cooling en-
ergy stored in the holding plate main-
OFF
tains the inside Minibar temperature.
The Minibar is completely noiseless
during the night.
2ND CYCLE
18-21
17-21
17-22
ADJUSTABLE
SWITCH ON/OFF
2ND CYCLE
17-22
17-23
17-23
ADJUSTABLE
SWITCH ON/OFF
K BASIC-K SMART-K ECOSMART_20-11-2017
AMBIENT TEMPERATURE
25°C
28°C
30°C
AMBIENT TEMPERATURE
≤ 25°C
≤ 28°C
≤ 30°C