Before performing any work on the blower, remove the connecting cord plug from the machine's socket.
Condition
Blower cuts out during operation
Runtime is too short
Battery jams when being inserted in charger
or the cord plug jams when being inserted in
the socket
Battery is not being charged even though
LED on charger glows green
LED on charger flashes red
1)
STIHL recommends an authorized STIHL servicing dealer.
BGA 100
Cause
Battery or blower's electronics too hot
Electrical or electromagnetic malfunction Disconnect and reconnect cord between
Battery not fully charged
Useful life of battery has been reached
or exceeded
Guides / contacts dirty
Battery too hot / too cold
(1 LED on battery glows red)
No electrical contact between charger
and battery
Fault in battery
(4 LEDs on battery flash red for
about 5 seconds)
Fault in charger
Remedy
Allow battery and blower to cool down
battery and blower.
Charge the battery
1)
Check battery
and replace
Carefully clean the guides / contacts
Allow battery to cool down / allow battery
to warm up slowly at temperatures of
about 15°C - 20°C (60°F - 70°F)
Operate charger only in closed, dry
rooms at ambient temperatures of +5 C -
+40 C (40°F - 104°F)
Remove the battery and refit it
Take the battery out of the charger and
refit it. Switch on the charger – if the
LEDs continue to flash, the battery has a
malfunction and must be replaced.
Have charger checked by your servicing
1)
dealer
English
41