English
3)
Electromagnetic interference or
fault. Take the battery out of the
belt bag and refit it. Switch on the
machine – if the LEDs continue to
flash, the battery has a malfunction
and must be replaced.
4)
Electromagnetic interference or
fault. Take the battery out of the
belt bag and pull the plug out of the
machine's socket. Use a blunt tool
to clean dirt off the contacts in the
belt bag and the connecting cord
plug. Refit the battery and insert the
connecting cord plug in the
machine's socket. Switch on the
power tool – if the light emitting
diodes still flash, the power tool is
faulty and must be checked by a
servicing dealer – STIHL
recommends an authorized STIHL
servicing dealer.
32
LED on Charger
1
The LED (1) on the charger may glow
continuously green or flash red.
Green continuous light ...
... indicates the following:
The battery
is being charged
–
is too hot and must cool down
–
before charging
See also "LEDs on battery".
The green LED on the charger goes off
as soon as the battery is fully charged.
Red flashing light ...
... may indicate the following:
No electrical contact between
–
battery and charger – remove and
refit the battery
Malfunction in battery – see also
–
"LEDs on Battery".
Malfunction in charger – have
–
checked by a servicing dealer.
STIHL recommends an authorized
STIHL servicing dealer.
Controls
Contents
3
1
2
1
Retaining latch
2
Trigger switch
3
LEDs
Function of Retaining Latch
Position ƒ
Blower is switched off.
–
Trigger switch is locked and cannot
–
be operated.
Position ‚
Blower is switched on.
–
Trigger switch is unlocked and can
–
be operated.
Selecting power level
Blowing power can be adjusted with the
retaining latch. Three power levels are
available.
BGA 100