Electrical Connection; Initial Start-Up - aqua technix AQUA Splash II Traduction Du Mode D'emploi Original

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17

5. Electrical Connection

All electrical connections should be performed by a qualified
expert only!
Make sure all parts are free of tension before doing any
maintenance work or electrical work.
The use of pumps for swimming pools and the restricted area
around them is only permitted if pumps are installed in accordance
with DIN/VDE 0100 part 702. The supply circuit has to be protected
with a fault current contactor with a nominal fault current of
I
30 mA.
Δ
N
Please make sure that the electrical installation has a disconnecting
device, which allows disconnecting from the power supply with a
minimum of 3 mm contact gap at each pole.
In accordance with norm requirements an electrical cable type
H05RN-F or H07RN-F must be used.
Please ensure that the diameter of the electrical cable used
adequately accommodates for the power of the motor and the
length of the cable. Pumps with single-phase motor are equipped
with a built-in overload switch.

6. Initial Start-up

Caution
Slowly fill the pump until the water level reaches the outlet
connection. Never operate the pump without water even when
checking the rotation direction of the motor!
Ensure that all valves in the suction and pressure lines are
completely open.
Before initial start-up and after extended periods of downtime
make sure the pump shaft turns freely.
7. Maintenance
Caution
Before carrying out any maintenance work, the electricity supply
to the pump must be switched off. Close the shut-off valves on the
suction and on the pressure line.
The strainer basket must be periodically emptied. A clogged
strainer basket will reduce the flow rate of the pump and lead to
insufficient filtration. The pump is to be thoroughly drained and
cleaned after extended periods of storage or down-time.
Caution
If there is danger of freezing during prolonged periods, the pump
must be drained ahead of time. For this purpose remove the
suction hose in order to drain off all liquid. Drain all pipes subject
to freezing.
Before doing any maintenance work, switch off the pump
and disconnect it from the power supply.
!
+20
+10
0
-10
-20
D42.02.315-P