Caution
When the pump is installed outside, we recommend to foresee a
simple protection against the weather (rain, sun etc.).
Caution
Implement appropriate measures to attenuate the noise generated
by the pump to avoid damage to the environment. Fastening the
pump to the foundation should be effected exclusively by means
of bolts, threads or dowels, in order to avoid blocking the removal
of the motor unit! Make sure that there is enough space between
fan cover and wall, minimum 60 mm.
Caution
We recommend the use of a spiral hose and a hose clamp to
connect the pump to the pool.
The connection to the pump is easy to undo and can be realised
in several ways due to the use of nozzles.
Caution
Keep the suction line as short as possible.
The pump should be installed horizontally
in a dry area. The Aqua Splash II is non-self
priming and must be installed below the water
level (up to 3 m max.). Suction and pressure
line are to be fitted with shut-off valves.