Technical Data
Minimum flow pressure
Operating pressure
Recommended operating pressure
Test pressure
Hot water temperature
Temperature scale
Safety stop
Flow capacity at bar
Hand shower (1)
Body showers, 6 jets (2)
Overhead shower (3)
Overhead shower + body showers
Hand + Overhead shower (4)
Flow heater:
Applicable for flow heaters at min. 24 kW and 1.5 bar flow
pressure before the Shower panel. Only one consumer pos-
sible, not two simul-taneously.
Pressure differences:
The pressures of the cold and hot water connections must
be balanced.
Safety instructions for connecting the DP Pre-
stige ML 20 with lighting:
You only require a socket for the electrical installation of the
Shower panel. An external transformer is supplied to operate
the lighting.
Electrical socket installation must only be performed by a
qualified electrician. The complete power supply runs via
a 230 V/50 Hz AC connection and must be protected by a
2-pole residual current operated circuit breaker with 30 mA
fault current.
The relevant national regulations in the applicable version
must be observed during electrical installation. Installation
and in spection tasks must be performed by authorized elec-
tricians. All work on the Shower Paneel must be performed
with the power disconnected.
The external transformer performance is 10 VA. A wiring
conduit with a diameter of at least 25 mm must be provided
to install the power supply cable. The transformer must be
installed in the dry area (protection zone 3). The cable pro-
vided allows the transformer to be installed max. approx. 7
m from the Shower Paneel. The transformer must be acces-
sible at all times. A damaged connection cable cannot be
replaced, and the transformer must not be operated in this
case.
1.5 bar
max. 10 bar
2 – 5 bar
16 bar
max. 70°C
20 – 60°C
38°C
15,3 l/min
20 l/min
14,5 l/min
24,4 l/min
26 l/min
From • the function is guaranteed.
Fittings / Technical Data / Safety Instructions