5. Operation

5.1 Room air controls

The ventilation unit can be operated with a
room air control. Suitable installation sites
for the room air control are, for example, a
central position in the living room or in a
corridor. The ventilation unit can be combined
with:
● Room air control RLS 1 WR (standard)
● Digital room air control RLS D1 WR
(option)
5.2 Operation with room air control
RLS 1 WR

5.2.1 Switching on the ventilation unit

 Press the ▲ button.
LED 1 flashes regularly at short intervals. The
fans in the ventilation unit start up. The
ventilation unit switches from standby mode
into interval operation (humidity protection
with fixed, defined cycle times; approx.
17 minutes on, approx. 13 minutes off).

5.2.2 Setting ventilation level

 Higher ventilation level: Press the ▲ button
as many times as necessary for the
required ventilation level LED to light up.
With each press, the ventilation unit switches
to a higher level. Ventilation level 1 /Interval
operation -> Ventilation level 1 /Continuous
operation (reduced ventilation) -> Ventilation
level 2 (nominal ventilation) -> Ventilation
level 3 (intensive ventilation)
64
LED 3
LED 2
LED 1
Plus button
Minus button
 Lower ventilation level: Press the ▼ button
as many times as necessary for the
required ventilation level LED to light up.
With each press, the ventilation unit switches
to a lower level: Ventilation level 3 -> Ventila-
tion level 2 -> Ventilation level 1/ Continuous
operation -> Ventilation level 1/ Interval
operation.

5.2.3 Switching off the ventilation unit

 Press the ▼ button as many times as
necessary for all three LEDs to be switched
off and no longer flash.
● The fans switch off. The ventilation unit is
in standby mode.
If the switch-off function is deactiva-
i
ted, the ventilation unit cannot be
switched off, see Chapter 5.2.4.

5.2.4 Ventilation levels

Ventilation level
Function
Off
Ventilation unit off - the
ventilation unit is in
standby mode.
The off function can be
deactivated by a
specialist installer
(jumper 9 bridged, see
Chapter 9.6.3). In this
case, the ventilation unit
can no longer be
switched off at the room
air control.
Ventilation
Frost protection
level 1 / Interval
ventilation: LED 1
operation
flashes regularly at short
intervals. The ventilation
unit runs with fixed,
defined cycle times in
interval operation.
Approx. 17 minutes at
ventilation level 1 and
then the ventilation unit
switches off for approx.
13 minutes, and so on.