● The ventilation unit is only
intended for domestic use and
similar purposes.
● It is only approved as a floor-
mounted unit or mounted on
the wall with the optional wall
bracket.
● The WR 300 or WR 400 may
only be used in line with the
calculations/layouts made by
the Engineering office.

4.3 Predictable misuses

Maico is not liable for damages
caused by use contrary to the
intended purpose.
Under no circumstances
should the unit be used:
● close to flammable materials,
liquids or gases.
● for the conveying of
chemicals, aggressive gases
or vapours.
● in potentially explosive atmos-
pheres.
● in swimming pools.
● for drying out new builds.
● in combination with laboratory
extractors.
● in combination with extractor
hoods that are connected
directly to the controlled
domestic ventilation exhaust
air channel.
It is not permitted to
i
integrate components in
the exhaust duct that
influence the temperature,
humidity or air volume. For
instance, it is forbidden to
connect a drying cabinet to
the exhaust duct because
this will result in corrosion
of metal parts on the inside
of the controlled domestic
ventilation unit.
For reasons energy usage,
i
we recommend using
extractor hoods in
circulating air mode.
4.4 Regulations for operation
with fireplaces
Observe the current rules from
the German Federation of Chim-
ney Sweeps (Evaluation criteria
for the joint operation of fire-
places – domestic ventilation –
extractor hoods) as well as
other pertinent regulations and
guidelines.
61