Installation instructions, only for experts

8. Starting-up

The function selection switch in the
low-voltage connection area allows
a variety of product functions to be
activated. The figure at the right
shows the standard setting for the
function selection switch.
Note that the control unit needs to
be switched off for 10 seconds after
making changes so that the settings
are saved.

8.1. Setting the heating period limit

The maximum heating period is set to 6 hours
as standard. The sauna control unit shuts down
automatically after the maximum heating period
for safety reasons.
The function selection switch in the low-voltage
connection area allows the maximum heat-
ing period to be set to 12 hours,18 hours or
24 hours. The required positions of the func-
tion selection switch can be found in the table
on the right.
!
The EN 60335-2-53 specifies a maximum heating period limit of 6 hours
for private saunas. For saunas in hotels, apartment blocks and similar
locations, a maximum heating period limit of 12 hours is permissible.
Extending the heating period limit to 18 hours or 24 hours is only
permitted in public saunas.
OFF
Fig. 5 Function selection switch –
Standard setting
Function
selection
switch
6 hours
12 hours
18 hours
24 hours
p. 21/30
EN
1
2
ON
ON
OFF
ON
ON
OFF
OFF
OFF