CONTROL CARD FOR TWO SINGLE-PHASE MOTORS 230V AC
The D760M panel features an electronic photocell control system which switches the external photo-
cell transmitter on and off thereby causing the control unit microprocessor to check whether the relay
switches correctly. If this does not happen, the control unit is automatically blocked.
•
MICROPROCESSOR-CONTROLLED LOGIC
•
SELF-DIAGNOSIS LED's
•
LINE INPUT FUSE
•
BUILT-IN TORQUE LIMITING DEVICE
•
ELECTRONIC CONTROL OF SAFETY DEVICES
•
PEDESTRIAN ENTRY FUNCTION
•
BUILT-IN FLASHING LIGHT CIRCUIT
•
433.92 MHz 2 CHANNEL BUILT-IN RADIO RECEIVER (CH)
•
"SLOW-DOWN" FUNCTION IN OPENING AND IN CLOSING PHASE
ATTENTION:
-
do not use single cables (with one single wire), ex. telephone cables, in order to avoid
breakdowns of the line and false contacts;
-
do not re-use old pre-existing cables.
TESTING
When all connections have been made:
•
All the green LED's must be on (each corresponds to a Normally Closed input).
•
They only turn off when the safeties they are associated with are active.
•
All the red LED's must be off (each corresponds to a Normally Open input) they only turn on when
the commands they are associated with are active.
•
The red Led DL7 must be always on (indicates the logic state of the control unit, see sect. "Diag-
nostics Led")
TECHNICAL CHARACTERISTICS
Power input to board
Max motors nominal power
Primary input line rapid fuse (F1 - 5x20)
Input voltage of motor circuits
Input voltage of auxiliary circuits
24Vac line rapid fuse (F2 - 5x20)
Logic circuit input voltage
Working temperature
Box protected to
TERMINAL BOARD CONNECTIONS
Key:
N.C. = Normally Closed - N.O. = Normally Open
Terminals
Function
POWER
1 - 2
SUPPLY
FLASHING
3 - 4
LIGHT
5 - 6 - 7
MOTOR M1
Description
POWER input 230Vac, 50Hz, single-phase;
1= PHASE, = EARTH, 2= NEUTRAL.
FLASHING LIGHT output 230Vac, 20W max. The signal is already
modulated for direct use. Flashing frequency is double during closing;
MOTOR M1 power output (opens the leaf fitted with the electric
lock), 230 Vac, max. 300 W. 5=CLOSE, 6=COMMON, 7=OPEN.
Notice: connect the capacitor between terminals 5 and 7;
D760M
230V AC - 50Hz
600 W ca.
F 3,15 A
230V AC
24V AC
F 500 mA
5V DC
-20°C ÷ + 55 °C
IP43
15