CONTROL CARD FOR TWO SINGLE-PHASE MOTORS 230V AC
The D760M panel features an electronic photocell control system which switches the external photo-
cell transmitter on and off thereby causing the control unit microprocessor to check whether the relay
switches correctly. If this does not happen, the control unit is automatically blocked.
MICROPROCESSOR-CONTROLLED LOGIC
SELF-DIAGNOSIS LED's
LINE INPUT FUSE
BUILT-IN TORQUE LIMITING DEVICE
ELECTRONIC CONTROL OF SAFETY DEVICES
PEDESTRIAN ENTRY FUNCTION
BUILT-IN FLASHING LIGHT CIRCUIT
433.92 MHz 2 CHANNEL BUILT-IN RADIO RECEIVER (CH)
"SLOW-DOWN" FUNCTION IN OPENING AND IN CLOSING PHASE
ATTENTION:
-
do not use single cables (with one single wire), ex. telephone cables, in order to avoid
breakdowns of the line and false contacts;
-
do not re-use old pre-existing cables.
TESTING
When all connections have been made:
All the green LED's must be on (each corresponds to a Normally Closed input).
They only turn off when the safeties they are associated with are active.
All the red LED's must be off (each corresponds to a Normally Open input) they only turn on when
the commands they are associated with are active.
The red Led DL7 must be always on (indicates the logic state of the control unit, see sect. "Diag-
nostics Led")

TECHNICAL CHARACTERISTICS

Power input to board
Max motors nominal power
Primary input line rapid fuse (F1 - 5x20)
Input voltage of motor circuits
Input voltage of auxiliary circuits
24Vac line rapid fuse (F2 - 5x20)
Logic circuit input voltage
Working temperature
Box protected to
TERMINAL BOARD CONNECTIONS
Key:
N.C. = Normally Closed - N.O. = Normally Open
Terminals
Function
POWER
1 - 2
SUPPLY
FLASHING
3 - 4
LIGHT
5 - 6 - 7
MOTOR M1
Description
POWER input 230Vac, 50Hz, single-phase;
1= PHASE, = EARTH, 2= NEUTRAL.
FLASHING LIGHT output 230Vac, 20W max. The signal is already
modulated for direct use. Flashing frequency is double during closing;
MOTOR M1 power output (opens the leaf fitted with the electric
lock), 230 Vac, max. 300 W. 5=CLOSE, 6=COMMON, 7=OPEN.
Notice: connect the capacitor between terminals 5 and 7;
D760M
230V AC - 50Hz
600 W ca.
F 3,15 A
230V AC
24V AC
F 500 mA
5V DC
-20°C ÷ + 55 °C
IP43
15

Publicité