7
MAN MODE
WARNING: with dip 7 ON the input OPEN / CLOSE (terminals 11-12) switches OPEN, the
PEDESTRIAN input (terminals 11-13) switches CLOSE.
In MAN mode, it is not necessary to run the race setup, and the dip-switches 1, 2, 3 and
4 are not used.
8
2nd RADIO CH
OPENING
9
RAM BLOW
SENSITIVE EDGE
10
SELECTION
JUMPER J1
Bridged=
following the connection of the external photocell contact (input 17 - 18), the gate
closes automatically after 5 seconds.
Not bridged=
function disconnected.
IMPORTANT:
Each pair of terminals attached to an NC contact that is not in use must be short-circuited in order to
ensure the proper operation of the board.
The door's earthing system must comply with current standards. The manufacturer will accept no li-
ability for any damage deriving from failure to comply with this requirement.
433.92 MHz BUILT-IN RADIO RECEIVER
The radio receiver can learn up to a maximum of 30 rolling codes (BUG2R, BUG4R, K-SLIM-RP, T-
4RP) which can be set on the two channels as required.
The first channel directly commands the control board for opening the automatic device; the second
channel commands a relay for a N.O. no-voltage output contact (terminals 21 and 22, max. 24 Vac, 1 A).
LEARNING SYSTEM FOR RADIO CONTROL DEVICES
P1 = OPEN/CLOSE
P2 = 2nd channel
1_ press button P1 briefly to associate a radio control device with the OPEN/CLOSE function;
2_ LED DL7 turns off to indicate that the code learning mode has been activated (if no code is entered
within 10 seconds, the board exits the programming mode);
3_ press the button of the relative radio control device;
4_ LED DL7 turns on again to indicate that the code has been memorised (if this does not happen,
wait 10 seconds and start again from point 1);
5_ to memorise codes to other radio control devices, repeat the procedure from point 1 up to a maxi-
mum of 30 transmitters;
6_ to memorise codes on the 2nd channel, repeat the procedure from point 1 using button P2 instead
of P1;
7_ to exit the learning mode without memorising a code, press button P1 or P2 briefly.
Notice: if the maximum number of radio control devices (30) is exceeded, LED DL7 flashes
rapidly for about 3 seconds without memorising the code.
REMOTE PROGRAMMING BY MEANS OF T-4RP and K-SLIM-RP (V 4.X)
With the new version of software V 4.X it is possible to carry out the remote self-learning of the new
enables the MAN mode: the OPEN / CLOSE input switches OPEN,
On
the PEDESTRIAN input switches CLOSE;
Off
Normal function
Bistable function active: To the impulse of transmitter the contact
On
is activated and remains activated until the next pressure.
Monostable function 2 sec active: To the impulse of transmitter
Off
the contact is activated and remains activated for 2 sec.
the "opening ram blow" function is on. This permits the release
On
of the electric lock (to be used only in the presence of an electric
lock);
Off
the "opening ram blow" function is off;
On
RESISTIVE SENSITIVE EDGE (terminal no. 15)
RESISTIVE EDGE - potential free contact N.C. (terminal no. 15)
Off
Note: if not used, keep the DIP in the OFF position.
D760M
19