The system operates according to these main phases:
1_ When the gate is not in operation the TWM base and TWC sensors remain on standby.
2_ The TWM base is activated by the control unit via the output "GATE OPEN INDICATOR".
Note: with the wired TWM base , do not connect any other device to the output "OPEN GATE
WARNING LIGHT" of the control board.
3_ On the opening pulse, the TWM base transmits a general activation command to the TWC sensors and
sets them to permanent reception status.
4_ When the automation is operating, the TWM base sends a signal to all programmed TWC sensors,
which in turn transmit the status of the sensitive edge and battery in sequence. The process is per-
formed continuously.
5_ If one or more TWC sensors are in alarm status, this condition is transmitted to the TWM base. The latter
opens the contact of the device in alarm status, causing automation shutdown.
6_ The TWM base remains active for a few seconds following automation shutdown, verified by means
of the input GATE OPEN INDICATOR. When the time interval elapses, the system returns to standby
status (point 1). The active phase is indicated by the red led (DL9) permanently lit.
7_ The presence of one or more TWC sensors with low battery charge is indicated by flashing of the rela-
tive green led.
Normal flashing: low battery.
Fast flashing: no wireless communication (dead battery, probable radio frequency interference, possible
problem with relevant sensor).
TECHNICAL SPECIFICATIONS
TWM board power supply
TWM board current absorption
TWC sensor power supply
Maximum range
Logic circuit power supply voltage
TWM housing protection rating
TWC housing protection rating
Operating temperature
DIAGNOSTICS LEDS
DL1
green led indicating FIXED SENSITIVE EDGE
DL2
green led indicating MOBILE SENSITIVE EDGE
DL3
green led indicating TX PHOTO 1
DL4
green led indicating TX PHOTO 2
DL5
green led indicating RX PHOTO 1
DL6
green led indicating RX PHOTO 2
DL7
green led indicating START-STOP
DL8
green led indicating FLASHING LIGHT
DL9
red led indicating OPERATION
INSTALLATION
All installation operations must be performed with the system disconnected from the power supply;
if fitted, the buffer battery must also be disconnected.
Preliminary checks
Carefully check that the operating parameters correspond to the data provided in the chapter "Technical
Specifications". If in doubt, do not use the product and request clarifications from the TAU technical assist-
ance service.
For fixture of the sensitive edge, follow the instructions supplied with the product.
To censure correct installation, proceed as follows:
1_ Position the TWC sensor in the vicinity of the sensitive edge, securing first the support bracket (1 fig.1)
by means of 2 screws (2 fig.1) suited to the gate structure. Insert the TWC board (3 fig.1) in the relative
supports on the base
2_ Connect the TWC sensor to the sensitive edge, routine the cables inside the gate (fig.2). Use cables
with sections of 0.5 mm².
TAU-WIRELESS
12/24 Vdc/Vac
70 mA
2 x AA 1.5V batteries
20 m
5 Vdc
IP 44
IP 43
-20 °C ÷ +70 °C
7