If the water flow is ok, flush the unit for approx. 60 minutes by opening the flush valve. If the
rejection rate increases, go on flushing until the value is acceptable. If the rate does not
improve, change the membrane.
6. Important Notes
-
Connection: Connect the reverse osmosis unit only to cold water supply. Higher temperatures
increase the pure water production but at temperatures above 40°C, the membrane will be
destroyed.
-
Stopping the unit: If you stop the unit, always close the tap water supply. If you run the unit
automatically with a solenoid valve, switch the valve between pre-filter and module. Take care
that waste water and pure water can flow away freely.
-
Disconnection of the unit: If you want to disconnect the unit for a longer period than 6
weeks, you should add disinfection liquid into the module housing. If the unit is started again,
flush it for 15 – 20 min. We recommend flushing also after shorter periods of stopping.
-
Storage: The unit has to be stored at temperatures above 0°C. Freezing would destroy the
membrane.
-
Temperature: At low temperatures in winter, the permeate production slows down.
7. Warranty
Should any defect in materials or workmanship be found within 24 months of the date of purchase,
AB Aqua Medic undertakes to repair, or at our option replace, the defective part free of charge –
always provided the product has been installed correctly, is used for the purpose that was intended
by us, is used in accordance with the operating instructions and is returned to us carriage paid.
Proof of Purchase is required by presentation of the original invoice or receipt indicating the
dealer's name, the model number and date of purchase, or a Guarantee Card if appropriate. This
warranty may not apply if any model or production number has been altered, deleted or removed,
unauthorised persons or organisations have executed repairs, modifications or alterations, or
damage is caused by accident, misuse or neglect. We regret we are unable to accept any liability
for any consequential loss. Please note that the product is not defective under the terms of this
Warranty where the product, or any of its component parts, was not originally designed and / or
manufactured for the market in which it is used. These statements do not affect your statutory
rights as a customer.
AB Aqua Medic GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany
Current manuals are available for download at www.aqua-medic.de.
- Technical changes reserved – 09/2018