5.0 POSSIBLE PROBLEMS AND THEIR SOLUTION
If required, our technical staff is at your disposal for telephone communication on 0039 0546 26834 during
working hours (08:00 - 12:30 / 14:00 - 17:30), or by fax 0039 0546 665653, or by e-mail at the address
assistenza@legaitaly.com. For any information or technical advice regarding the machine; however, before
contacting us, please check the information below.
Problem found
The gears do not rotate Check that there are no foreign
Honey percolates from
the front panel
The dosing machine
does not aspire
The dosing machine
does not respond to
commands
Honey comes out with
a large amount of air
The doses are not
regular
The jet of honey is not
centred
The dosing machine
does not turn on
LEGA
srl
Costruzioni Apistiche – via Maestri del Lavoro 23 – 48018 Faenza
www.legaitaly.com - Tel 054626834 – Fax 054628279 – P.iva 00043230390
Cause
bodies inside the pump body. Fig 7
page 4
Insufficient tightening of the 6 black
knobs or absence of the red seal
Tightening problems
Electronic problem
Imperfect tightening
Presence of air in honey
Rotation of the gears too fast in
relation to the density of the honey
Power line interrupted
Solution
Remove the foreign body.
Further tighten the 6 black knobs, reinsert
the red seal
Check the gaskets on the pump
Check the tightness of the knobs on the
pump cover, the honey inlet pipe, the
honey outlet nozzle and the manual filling
collar.
Check the tightening of the pipe anchor
clamps.
Check that there are no leaks along the
loading tube.
Check the correct assembly of the non-
return valve, if used.
Switch off the dosing machine and switch
it on again after at least 10 seconds. If the
problem persists contact the assistance
Check the tightening
Check the tightening
Reduce the rotation speed of the gears (33
fig L)
Check the connection to the mains
Check the connection to the power supply
Check the fuses located in the power
supply unit
Check the fuses on the back of the dosing
machine
36 / 95