SEVERIN KS 9878 Mode D'emploi page 16

Masquer les pouces Voir aussi pour KS 9878:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
Problem
The appliance is not working at all.
The temperature inside the
compartment is not low enough.
The normal operating sound
changes or becomes louder.
Water is collecting on the bottom
of the unit.
Transporting the appliance
To prevent damage to the unit during transport, ensure that
all accessories and components inside and around the
appliance are securely fastened.
The unit must only be transported in its vertical position; do
not tilt any more than 30°.
Once the unit has been positioned, wait for about 30
minutes before it is connected to the mains.
If the unit has been tilted more than 30° during transport,
allow it to stand in an upright position for at least 4 hours
before it is connected to the mains.
Disposal
Devices marked with this symbol must be
disposed of separately from your household
waste, as they contain valuable materials which
can be recycled. Proper disposal protects the
environment and human health. Your local authority or
retailer can provide information on the matter. Remove the
plug from the wall socket and render the unit unusable by
cutting off the power cord prior to disposal.
The cooling medium Isobutane (R600a) and
the propellant in the isolation Cyclopentane
(C5H10) are inflammable substances, thus,
need to be appropriately disposed of.
∙ Make sure the tubes of the cooling circuit don't get
damaged before the proper disposal.
Manufacturer
Severin Elektrogeräte GmbH, Röhre 27,
59846 Sundern, Germany
16
Possible cause and solution
∙ There is a power failure
∙ The main fuse has blown.
∙ The temperature control is set to '0'.
∙ The fuse in the wall socket (if applicable) has blown. This can be checked by
connecting another electrical device to the socket and checking for function.
∙ The cabinet has been overloaded.
∙ The door is not properly closed.
∙ There is too much dust on the condenser.
∙ Insufficient ventilation: the unit is too close to a wall or other structure or object.
∙ The temperature setting is too low
Check the following:
∙ Check for proper positioning (uneven floor).
∙ Are any adjacent objects affected by the running of the cooling unit (i.e. causing
them to vibrate?)
∙ Are there any objects on top of the unit which might be vibrating?
The melt-water drain system is blocked. Remove the blockage and clean the system.
Guarantee
SEVERIN grants you a manufacturer's guarantee of
two years from the date of purchase. During this period,
we will eliminate all defects free of charge that are
demonstrably based on material or manufacturing defects
and that significantly impair function. Further claims are
excluded. The following are excluded from the guarantee:
Damage that can be traced back to non-observance of
the instructions for use, improper handling or normal wear
and tear, as well as easily breakable parts such as glass,
plastic or incandescent lights. The guarantee expires in the
event of any interference not authorised by SEVERIN. The
statutory guarantee rights toward the seller and any seller
guarantees remain unaffected.
Information needed by the Customer Service
Should repairs to the appliance become necessary, please
contact our Customer Service, providing a detailed fault
description and quoting the article number KS ... on the
rating label of the appliance (inside the cabinet at the
bottom left). This information will help us to handle your
request efficiently.
In case of problems or malfunction, or if spare parts
are required, contact only the Service hotline.

Publicité

Table des Matières
loading

Table des Matières